Options
Kramer, Franz-Josef
Loading...
Preferred name
Kramer, Franz-Josef
Official Name
Kramer, Franz-Josef
Alternative Name
Kramer, F.-J.
Kramer, Franz Josef
Kramer, F. J.
Kramer, Franz-Joseph
Kramer, Franz Joseph
Main Affiliation
Now showing 1 - 2 of 2
2011Journal Article [["dc.bibliographiccitation.firstpage","1057"],["dc.bibliographiccitation.issue","6"],["dc.bibliographiccitation.journal","The Angle Orthodontist"],["dc.bibliographiccitation.lastpage","1063"],["dc.bibliographiccitation.volume","81"],["dc.contributor.author","Hahn, Wolfram"],["dc.contributor.author","Engelke, Benjamin"],["dc.contributor.author","Jung, Klaus"],["dc.contributor.author","Dathe, Henning"],["dc.contributor.author","Kramer, Franz-Joseph"],["dc.contributor.author","Roedig, Tina"],["dc.contributor.author","Kubein-Meesenburg, Dietmar"],["dc.contributor.author","Gruber, Rudolf Matthias"],["dc.date.accessioned","2018-11-07T08:50:19Z"],["dc.date.available","2018-11-07T08:50:19Z"],["dc.date.issued","2011"],["dc.description.abstract","Objective: To determine the forces and moments delivered to a maxillary central incisor during rotation with aligners when a simulated occlusal force generated during swallowing acts on the appliance. Materials and Methods: Five identical appliances were manufactured from four different starting materials (Erkodur 0.8 mm and 1.0 mm; Biolon 0.75 mm and 1.0 mm). An upper central incisor fixed in a measuring device was rotated around its central axis in 0.5-degree steps up to +/- 10 degrees with the appliance fixed in place. An occlusal force of 30 N generated during swallowing was simulated with a weight positioned on the appliance. For statistical analysis, the moments Tz (rotation) and forces Fz (intrusion) at a deflection of +/- 0.34 mm to the incisor edge (+/- 5 degrees rotation) were tested. Means and standard deviations for Tz and median and 25% and 75% quartiles for Fz were calculated. An analysis of variance was performed. Results: The simulated occlusal force increased the measured intrusive force Fz (maximum with a weight, -3.7 N [-3.7, -2.4]; minimum without a weight, -1.3 N [-1.4, -1.1]) and the rotary moment Tz (maximum with a weight, -50.8 Nmm [+/- 0.8]; minimum without a weight, 18.2 Nmm [+/- 0.9]) significantly in all cases (P < .01). This was found for all materials measured and for both directions of rotation. Conclusion: During rotation with aligners, a simulated occlusal force increases the intrusive force and the rotary moment. The biological adverse side effects of these phenomena remain unclear, especially in patients with periods of bruxism. (Angle Orthod. 2011;81:1057-1063.)"],["dc.identifier.doi","10.2319/013111-62.1"],["dc.identifier.isi","000296484900019"],["dc.identifier.pmid","21612314"],["dc.identifier.purl","https://resolver.sub.uni-goettingen.de/purl?gs-1/8018"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/21669"],["dc.notes.intern","Merged from goescholar"],["dc.notes.status","zu prĂĽfen"],["dc.notes.submitter","Najko"],["dc.publisher","E H Angle Education Research Foundation, Inc"],["dc.relation.issn","0003-3219"],["dc.rights","Goescholar"],["dc.rights.uri","https://goescholar.uni-goettingen.de/licenses"],["dc.title","The influence of occlusal forces on force delivery properties of aligners during rotation of an upper central incisor"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.status","published"],["dc.type.version","published_version"],["dspace.entity.type","Publication"]]Details DOI PMID PMC WOS2012Journal Article [["dc.bibliographiccitation.firstpage","145"],["dc.bibliographiccitation.issue","1"],["dc.bibliographiccitation.journal","The Angle Orthodontist"],["dc.bibliographiccitation.lastpage","150"],["dc.bibliographiccitation.volume","82"],["dc.contributor.author","Fricke-Zech, Susanne"],["dc.contributor.author","Gruber, Rudolf Matthias"],["dc.contributor.author","Dullin, Christian"],["dc.contributor.author","Zapf, Antonia"],["dc.contributor.author","Kramer, Franz-Josef"],["dc.contributor.author","Kubein-Meesenburg, Dietmar"],["dc.contributor.author","Hahn, Wolfram"],["dc.date.accessioned","2018-11-07T09:15:56Z"],["dc.date.available","2018-11-07T09:15:56Z"],["dc.date.issued","2012"],["dc.description.abstract","Objective: To conduct a pilot study to investigate the potentiality to determine the midpalatal sutural width radiographically with a flat-panel volume computed tomography (fpVCT) in a porcine model. Materials and Methods: Bone samples from the midpalatal suture of five young (16 weeks) and five old (200 weeks) sus scrofa domestica were gathered. The midpalatal suture width was measured via fpVCT and compared to respective histological preparations. Results with P < .05 were considered significant. Results: The data obtained by fpVCT and by histomorphometric analysis reveal a highly significant age dependency of the measured suture width (both P < .0001), with lower suture width values in older subjects compared to the younger group. The averaged suture widths measured in the fpVCT images shows a distinctively higher mean compared to the histomorphometric data with high statistical significance (P < .0001). The evaluated difference between both methods was almost constant. Conclusion: fpVCT is a powerful tool for determining midpalatal sutural width. (Angle Orthod. 2012;82:145-150.)"],["dc.identifier.doi","10.2319/040311-238.1"],["dc.identifier.isi","000299136300022"],["dc.identifier.pmid","21812573"],["dc.identifier.purl","https://resolver.sub.uni-goettingen.de/purl?gs-1/9971"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/27819"],["dc.notes.intern","Merged from goescholar"],["dc.notes.status","zu prĂĽfen"],["dc.notes.submitter","Najko"],["dc.publisher","E H Angle Education Research Foundation, Inc"],["dc.relation.issn","0003-3219"],["dc.rights","Goescholar"],["dc.rights.uri","https://goescholar.uni-goettingen.de/licenses"],["dc.title","Measurement of the midpalatal suture width A comparison of flat-panel volume computed tomography to histomorphometric analysis in a porcine model"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.status","published"],["dc.type.version","published_version"],["dspace.entity.type","Publication"]]Details DOI PMID PMC WOS