Now showing 1 - 6 of 6
  • 2011Conference Paper
    [["dc.contributor.author","Kalbfleisch, Sebastian"],["dc.contributor.author","Neubauer, Heike"],["dc.contributor.author","Krüger, Sven P"],["dc.contributor.author","Bartels, Matthias"],["dc.contributor.author","Osterhoff, Markus"],["dc.contributor.author","Mai, Dong-Du"],["dc.contributor.author","Giewekemeyer, Klaus"],["dc.contributor.author","Hartmann, Britta"],["dc.contributor.author","Sprung, Michael"],["dc.contributor.author","Salditt, Tim"],["dc.contributor.author","McNulty, Ian"],["dc.contributor.author","Eyberger, Catherine"],["dc.contributor.author","Lai, Barry"],["dc.date.accessioned","2017-09-07T11:54:07Z"],["dc.date.available","2017-09-07T11:54:07Z"],["dc.date.issued","2011"],["dc.identifier.doi","10.1063/1.3625313"],["dc.identifier.gro","3145117"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/2818"],["dc.language.iso","en"],["dc.notes.intern","Crossref Import"],["dc.notes.status","public"],["dc.publisher","AIP Publishing"],["dc.publisher.place","Melville, NY"],["dc.relation","SFB 755: Nanoscale Photonic Imaging"],["dc.relation.conference","10th International Conference on X-Ray Microscopy"],["dc.relation.eventend","2010-08-20"],["dc.relation.eventlocation","Chicago, Illinois"],["dc.relation.eventstart","2010-08-15"],["dc.relation.isbn","0-7354-0925-0"],["dc.relation.isbn","978-0-7354-0925-5"],["dc.relation.ispartof","The 10th International Conference on X-Ray Microscopy"],["dc.relation.orgunit","Institut für Röntgenphysik"],["dc.relation.workinggroup","RG Salditt (Structure of Biomolecular Assemblies and X-Ray Physics)"],["dc.subject.gro","x-ray optics"],["dc.subject.gro","x-ray imaging"],["dc.title","The Göttingen Holography Endstation of Beamline P10 at PETRA III∕DESY"],["dc.type","conference_paper"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","no"],["dspace.entity.type","Publication"]]
    Details DOI
  • 2010Conference Paper
    [["dc.contributor.author","Kalbfleisch, Sebastian"],["dc.contributor.author","Osterhoff, Markus"],["dc.contributor.author","Giewekemeyer, Klaus"],["dc.contributor.author","Neubauer, Heike"],["dc.contributor.author","Krüger, Sven P"],["dc.contributor.author","Hartmann, Britta"],["dc.contributor.author","Bartels, Matthias"],["dc.contributor.author","Sprung, Michael"],["dc.contributor.author","Leupold, O."],["dc.contributor.author","Siewert, F."],["dc.contributor.author","Salditt, Tim"],["dc.contributor.author","Garrett, R."],["dc.contributor.author","Gentle, I."],["dc.contributor.author","Nugent, K."],["dc.contributor.author","Wilkins, S."],["dc.date.accessioned","2017-09-07T11:54:07Z"],["dc.date.available","2017-09-07T11:54:07Z"],["dc.date.issued","2010"],["dc.identifier.doi","10.1063/1.3463233"],["dc.identifier.gro","3145119"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/2820"],["dc.language.iso","en"],["dc.notes.intern","Crossref Import"],["dc.notes.status","public"],["dc.publisher","AIP Publishing"],["dc.publisher.place","Melville, NY"],["dc.relation","SFB 755: Nanoscale Photonic Imaging"],["dc.relation.conference","10th International Conference on Synchrotron Radiation Instrumentation"],["dc.relation.eventend","2009-10-02"],["dc.relation.eventlocation","Melbourne, Australia"],["dc.relation.eventstart","2009-09-27"],["dc.relation.isbn","978-0-7354-0782-4"],["dc.relation.ispartof","SRI 2009: the 10th International Conference on Synchrotron Radiation Instrumentation"],["dc.relation.orgunit","Institut für Röntgenphysik"],["dc.relation.workinggroup","RG Salditt (Structure of Biomolecular Assemblies and X-Ray Physics)"],["dc.subject.gro","x-ray optics"],["dc.subject.gro","x-ray imaging"],["dc.title","The holography endstation of beamline P10 at PETRA III"],["dc.type","conference_paper"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","no"],["dspace.entity.type","Publication"]]
    Details DOI
  • 2011Journal Article Research Paper
    [["dc.bibliographiccitation.artnumber","023804"],["dc.bibliographiccitation.issue","2"],["dc.bibliographiccitation.journal","Physical Review A"],["dc.bibliographiccitation.volume","83"],["dc.contributor.author","Giewekemeyer, Klaus"],["dc.contributor.author","Krueger, S. P."],["dc.contributor.author","Kalbfleisch, Sebastian"],["dc.contributor.author","Bartels, Matthias"],["dc.contributor.author","Beta, C."],["dc.contributor.author","Salditt, Tim"],["dc.date.accessioned","2017-09-07T11:44:21Z"],["dc.date.available","2017-09-07T11:44:21Z"],["dc.date.issued","2011"],["dc.description.abstract","We have used x-ray waveguides as highly confining optical elements for nanoscale imaging of unstained biological cells using the simple geometry of in-line holography. The well-known twin-image problem is effectively circumvented by a simple and fast iterative reconstruction. The algorithm which combines elements of the classical Gerchberg-Saxton scheme and the hybrid-input-output algorithm is optimized for phase-contrast samples, well-justified for imaging of cells at multi-keV photon energies. The experimental scheme allows for a quantitative phase reconstruction from a single holographic image without detailed knowledge of the complex illumination function incident on the sample, as demonstrated for freeze-dried cells of the eukaryotic amoeba Dictyostelium discoideum. The accessible resolution range is explored by simulations, indicating that resolutions on the order of 20 nm are within reach applying illumination times on the order of minutes at present synchrotron sources."],["dc.identifier.doi","10.1103/PhysRevA.83.023804"],["dc.identifier.gro","3142778"],["dc.identifier.isi","000287029900011"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/219"],["dc.language.iso","en"],["dc.notes.intern","WoS Import 2017-03-10"],["dc.notes.status","final"],["dc.notes.submitter","PUB_WoS_Import"],["dc.relation.issn","1050-2947"],["dc.relation.orgunit","Institut für Röntgenphysik"],["dc.relation.workinggroup","RG Salditt (Structure of Biomolecular Assemblies and X-Ray Physics)"],["dc.subject.gro","x-ray optics"],["dc.subject.gro","x-ray imaging"],["dc.title","X-ray propagation microscopy of biological cells using waveguides as a quasipoint source"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.subtype","original_ja"],["dspace.entity.type","Publication"]]
    Details DOI WOS
  • 2010Journal Article Research Paper
    [["dc.bibliographiccitation.artnumber","091102"],["dc.bibliographiccitation.issue","9"],["dc.bibliographiccitation.journal","Applied Physics Letters"],["dc.bibliographiccitation.volume","96"],["dc.contributor.author","Schropp, A."],["dc.contributor.author","Boye, P."],["dc.contributor.author","Feldkamp, J. M."],["dc.contributor.author","Hoppe, R."],["dc.contributor.author","Patommel, Jens"],["dc.contributor.author","Samberg, D."],["dc.contributor.author","Stephan, S."],["dc.contributor.author","Giewekemeyer, Klaus"],["dc.contributor.author","Wilke, Robin N."],["dc.contributor.author","Salditt, Tim"],["dc.contributor.author","Gulden, J."],["dc.contributor.author","Mancuso, A. P."],["dc.contributor.author","Vartanyants, I. A."],["dc.contributor.author","Weckert, E."],["dc.contributor.author","Schoeder, S."],["dc.contributor.author","Burghammer, Manfred"],["dc.contributor.author","Schroer, C. G."],["dc.date.accessioned","2017-09-07T11:46:07Z"],["dc.date.available","2017-09-07T11:46:07Z"],["dc.date.issued","2010"],["dc.description.abstract","We have carried out a ptychographic scanning coherent diffraction imaging experiment on a test object in order to characterize the hard x-ray nanobeam in a scanning x-ray microscope. In addition to a high resolution image of the test object, a detailed quantitative picture of the complex wave field in the nanofocus is obtained with high spatial resolution and dynamic range. Both are the result of high statistics due to the large number of diffraction patterns. The method yields a complete description of the focus, is robust against inaccuracies in sample positioning, and requires no particular shape or prior knowledge of the test object."],["dc.identifier.doi","10.1063/1.3332591"],["dc.identifier.gro","3142954"],["dc.identifier.isi","000275246200002"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/415"],["dc.language.iso","en"],["dc.notes.intern","WoS Import 2017-03-10"],["dc.notes.status","final"],["dc.notes.submitter","PUB_WoS_Import"],["dc.relation.issn","0003-6951"],["dc.relation.orgunit","Institut für Röntgenphysik"],["dc.relation.workinggroup","RG Salditt (Structure of Biomolecular Assemblies and X-Ray Physics)"],["dc.subject.gro","x-ray optics"],["dc.subject.gro","x-ray imaging"],["dc.title","Hard x-ray nanobeam characterization by coherent diffraction microscopy"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.subtype","original_ja"],["dspace.entity.type","Publication"]]
    Details DOI WOS
  • 2013Journal Article Research Paper
    [["dc.bibliographiccitation.firstpage","490"],["dc.bibliographiccitation.issue","3"],["dc.bibliographiccitation.journal","Journal of Synchrotron Radiation"],["dc.bibliographiccitation.lastpage","497"],["dc.bibliographiccitation.volume","20"],["dc.contributor.author","Giewekemeyer, Klaus"],["dc.contributor.author","Wilke, Robin N."],["dc.contributor.author","Osterhoff, Markus"],["dc.contributor.author","Bartels, Matthias"],["dc.contributor.author","Kalbfleisch, Sebastian"],["dc.contributor.author","Salditt, Tim"],["dc.date.accessioned","2020-11-05T15:05:25Z"],["dc.date.available","2020-11-05T15:05:25Z"],["dc.date.issued","2013"],["dc.description.abstract","In the past decade Kirkpatrick-Baez (KB) mirrors have been established as powerful focusing systems in hard X-ray microscopy applications. Here a ptychographic characterization of the KB focus in the dedicated nano-imaging setup GINIX (Gottingen Instrument for Nano-Imaging with X-rays) at the P10 coherence beamline of the PETRA III synchrotron at HASLYLAB/DESY, Germany, is reported. More specifically, it is shown how aberrations in the KB beam, caused by imperfections in the height profile of the focusing mirrors, can be eliminated using a pinhole as a spatial filter near the focal plane. A combination of different pinhole sizes and illumination conditions of the KB setup makes the prepared optical setup well suited not only for high-resolution ptychographic coherent X-ray diffractive imaging but also for moderate-resolution/large-field-of-view propagation imaging in the divergent KB beam."],["dc.identifier.doi","10.1107/S0909049513005372"],["dc.identifier.gro","3142357"],["dc.identifier.isi","000317604800013"],["dc.identifier.pmid","23592629"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/68466"],["dc.language.iso","en"],["dc.notes.intern","DOI Import GROB-352.6"],["dc.notes.status","final"],["dc.notes.submitter","PUB_WoS_Import"],["dc.relation.issn","0909-0495"],["dc.relation.orgunit","Institut für Röntgenphysik"],["dc.relation.workinggroup","RG Salditt (Structure of Biomolecular Assemblies and X-Ray Physics)"],["dc.subject.gro","x-ray optics"],["dc.subject.gro","x-ray imaging"],["dc.title","Versatility of a hard X-ray Kirkpatrick–Baez focus characterized by ptychography"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.subtype","original_ja"],["dspace.entity.type","Publication"]]
    Details DOI PMID PMC WOS
  • 2009Journal Article Research Paper
    [["dc.bibliographiccitation.artnumber","184112"],["dc.bibliographiccitation.issue","18"],["dc.bibliographiccitation.journal","Physical Review B"],["dc.bibliographiccitation.volume","79"],["dc.contributor.author","Salditt, Tim"],["dc.contributor.author","Giewekemeyer, Klaus"],["dc.contributor.author","Fuhse, Christian"],["dc.contributor.author","Krueger, S. P."],["dc.contributor.author","Tucoulou, Remi"],["dc.contributor.author","Cloetens, Peter"],["dc.date.accessioned","2017-09-07T11:47:28Z"],["dc.date.available","2017-09-07T11:47:28Z"],["dc.date.issued","2009"],["dc.description.abstract","We report a projection phase contrast microscopy experiment using hard x-ray pink beam undulator radiation focused by an adaptive mirror system to 100-200 nm spot size. This source is used to illuminate a lithographic test pattern with a well-controlled range of spatial frequencies. The oscillatory nature of the contrast transfer function with source-to-sample distance in this holographic imaging scheme is quantified and the validity of the weak phase object approximation is confirmed for the experimental conditions."],["dc.identifier.doi","10.1103/PhysRevB.79.184112"],["dc.identifier.gro","3143121"],["dc.identifier.isi","000266501200041"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/600"],["dc.language.iso","en"],["dc.notes.intern","WoS Import 2017-03-10 / Funder: Deutsche Forschungsgemeinschaft [SFB755]"],["dc.notes.status","final"],["dc.notes.submitter","PUB_WoS_Import"],["dc.relation.issn","1098-0121"],["dc.relation.orgunit","Institut für Röntgenphysik"],["dc.relation.workinggroup","RG Salditt (Structure of Biomolecular Assemblies and X-Ray Physics)"],["dc.subject.gro","x-ray optics"],["dc.subject.gro","x-ray imaging"],["dc.title","Projection phase contrast microscopy with a hard x-ray nanofocused beam: Defocus and contrast transfer"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.subtype","original_ja"],["dspace.entity.type","Publication"]]
    Details DOI WOS