Options
Moneron, Gael
Loading...
Preferred name
Moneron, Gael
Official Name
Moneron, Gael
Alternative Name
Moneron, G.
Now showing 1 - 2 of 2
2011Journal Article Research Paper [["dc.bibliographiccitation.firstpage","571"],["dc.bibliographiccitation.issue","7"],["dc.bibliographiccitation.journal","Nature Methods"],["dc.bibliographiccitation.lastpage","573"],["dc.bibliographiccitation.volume","8"],["dc.contributor.author","Vicidomini, Giuseppe"],["dc.contributor.author","Moneron, Gael"],["dc.contributor.author","Han, Kyu Young"],["dc.contributor.author","Westphal, Volker"],["dc.contributor.author","Ta, Haisen"],["dc.contributor.author","Reuss, Matthias"],["dc.contributor.author","Engelhardt, Johann"],["dc.contributor.author","Eggeling, Christian"],["dc.contributor.author","Hell, Stefan"],["dc.date.accessioned","2017-09-07T11:44:10Z"],["dc.date.available","2017-09-07T11:44:10Z"],["dc.date.issued","2011"],["dc.description.abstract","Applying pulsed excitation together with time-gated detection improves the fluorescence on-off contrast in continuous-wave stimulated emission depletion (CW-STED) microscopy, thus revealing finer details in fixed and living cells using moderate light intensities. This method also enables super-resolution fluorescence correlation spectroscopy with CW-STED beams, as demonstrated by quantifying the dynamics of labeled lipid molecules in the plasma membrane of living cells."],["dc.identifier.doi","10.1038/NMETH.1624"],["dc.identifier.gro","3142707"],["dc.identifier.isi","000292194500020"],["dc.identifier.pmid","21642963"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/141"],["dc.language.iso","en"],["dc.notes.intern","WoS Import 2017-03-10"],["dc.notes.status","final"],["dc.notes.submitter","PUB_WoS_Import"],["dc.relation.issn","1548-7091"],["dc.title","Sharper low-power STED nanoscopy by time gating"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.subtype","original"],["dspace.entity.type","Publication"]]Details DOI PMID PMC WOS2013Journal Article Research Paper [["dc.bibliographiccitation.artnumber","e54421"],["dc.bibliographiccitation.issue","1"],["dc.bibliographiccitation.journal","PLoS ONE"],["dc.bibliographiccitation.volume","8"],["dc.contributor.author","Vicidomini, Giuseppe"],["dc.contributor.author","Schoenle, Andreas"],["dc.contributor.author","Ta, Haisen"],["dc.contributor.author","Han, Kyu Young"],["dc.contributor.author","Moneron, Gael"],["dc.contributor.author","Eggeling, Christian"],["dc.contributor.author","Hell, Stefan"],["dc.date.accessioned","2017-09-07T11:48:18Z"],["dc.date.available","2017-09-07T11:48:18Z"],["dc.date.issued","2013"],["dc.description.abstract","In a stimulated emission depletion (STED) microscope the region in which fluorescence markers can emit spontaneously shrinks with continued STED beam action after a singular excitation event. This fact has been recently used to substantially improve the effective spatial resolution in STED nanoscopy using time-gated detection, pulsed excitation and continuous wave (CW) STED beams. We present a theoretical framework and experimental data that characterize the time evolution of the effective point-spread-function of a STED microscope and illustrate the physical basis, the benefits, and the limitations of time-gated detection both for CW and pulsed STED lasers. While gating hardly improves the effective resolution in the all-pulsed modality, in the CW-STED modality gating strongly suppresses low spatial frequencies in the image. Gated CW-STED nanoscopy is in essence limited (only) by the reduction of the signal that is associated with gating. Time-gated detection also reduces/suppresses the influence of local variations of the fluorescence lifetime on STED microscopy resolution."],["dc.identifier.doi","10.1371/journal.pone.0054421"],["dc.identifier.gro","3142402"],["dc.identifier.isi","000313872800053"],["dc.identifier.pmid","23349884"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/7885"],["dc.language.iso","en"],["dc.notes.intern","WoS Import 2017-03-10"],["dc.notes.status","final"],["dc.notes.submitter","PUB_WoS_Import"],["dc.relation.issn","1932-6203"],["dc.title","STED Nanoscopy with Time-Gated Detection: Theoretical and Experimental Aspects"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.subtype","original"],["dspace.entity.type","Publication"]]Details DOI PMID PMC WOS