Options
Muceli, Silvia
Loading...
Preferred name
Muceli, Silvia
Official Name
Muceli, Silvia
Alternative Name
Muceli, S.
Main Affiliation
Now showing 1 - 3 of 3
2019Journal Article [["dc.bibliographiccitation.artnumber","eaau2956"],["dc.bibliographiccitation.issue","1"],["dc.bibliographiccitation.journal","Science Advances"],["dc.bibliographiccitation.lastpage","eaau2956"],["dc.bibliographiccitation.volume","5"],["dc.contributor.author","Bergmeister, Konstantin D."],["dc.contributor.author","Aman, Martin"],["dc.contributor.author","Muceli, Silvia"],["dc.contributor.author","Vujaklija, Ivan"],["dc.contributor.author","Manzano-Szalai, Krisztina"],["dc.contributor.author","Unger, Ewald"],["dc.contributor.author","Byrne, Ruth A."],["dc.contributor.author","Scheinecker, Clemens"],["dc.contributor.author","Riedl, Otto"],["dc.contributor.author","Salminger, Stefan"],["dc.contributor.author","Frommlet, Florian"],["dc.contributor.author","Borschel, Gregory H."],["dc.contributor.author","Farina, Dario"],["dc.contributor.author","Aszmann, Oskar C."],["dc.date.accessioned","2019-07-09T11:50:25Z"],["dc.date.available","2019-07-09T11:50:25Z"],["dc.date.issued","2019"],["dc.description.abstract","Selective nerve transfers surgically rewire motor neurons and are used in extremity reconstruction to restore muscle function or to facilitate intuitive prosthetic control. We investigated the neurophysiological effects of rewiring motor axons originating from spinal motor neuron pools into target muscles with lower innervation ratio in a rat model. Following reinnervation, the target muscle's force regenerated almost completely, with the motor unit population increasing to 116% in functional and 172% in histological assessments with subsequently smaller muscle units. Muscle fiber type populations transformed into the donor nerve's original muscles. We thus demonstrate that axons of alternative spinal origin can hyper-reinnervate target muscles without loss of muscle force regeneration, but with a donor-specific shift in muscle fiber type. These results explain the excellent clinical outcomes following nerve transfers in neuromuscular reconstruction. They indicate that reinnervated muscles can provide an accurate bioscreen to display neural information of lost body parts for high-fidelity prosthetic control."],["dc.identifier.doi","10.1126/sciadv.aau2956"],["dc.identifier.pmid","30613770"],["dc.identifier.purl","https://resolver.sub.uni-goettingen.de/purl?gs-1/15938"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/59771"],["dc.language.iso","en"],["dc.notes.intern","Merged from goescholar"],["dc.relation","info:eu-repo/grantAgreement/EC/FP7/267888/EU//DEMOVE"],["dc.relation.issn","2375-2548"],["dc.rights","CC BY-NC 4.0"],["dc.rights.uri","https://creativecommons.org/licenses/by-nc/4.0"],["dc.subject.ddc","610"],["dc.title","Peripheral nerve transfers change target muscle structure and function"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.version","published_version"],["dspace.entity.type","Publication"]]Details DOI PMID PMC2017-10-16Journal Article [["dc.bibliographiccitation.artnumber","13300"],["dc.bibliographiccitation.issue","1"],["dc.bibliographiccitation.journal","Scientific reports"],["dc.bibliographiccitation.volume","7"],["dc.contributor.author","Vieira, Taian Martins"],["dc.contributor.author","Botter, Alberto"],["dc.contributor.author","Muceli, Silvia"],["dc.contributor.author","Farina, Dario"],["dc.date.accessioned","2019-07-09T11:44:31Z"],["dc.date.available","2019-07-09T11:44:31Z"],["dc.date.issued","2017-10-16"],["dc.description.abstract","The relatively large pick-up volume of surface electrodes has for long motivated the concern that muscles other than that of interest may contribute to surface electromyograms (EMGs). Recent findings suggest however the pick-up volume of surface electrodes may be smaller than previously appreciated, possibly leading to the detection of surface EMGs insensitive to muscle activity. Here we combined surface and intramuscular recordings to investigate how comparably action potentials from gastrocnemius and soleus are represented in surface EMGs detected with different inter-electrode distances. We computed the firing instants of motor units identified from intramuscular EMGs detected from gastrocnemius and soleus while five participants stood upright. We used these instants to trigger and average surface EMGs detected from multiple skin regions along gastrocnemius. Results from 66 motor units (whereof 31 from gastrocnemius) revealed the surface-recorded amplitude of soleus action potentials was 6% of that of gastrocnemius and did not decrease for inter-electrode distances smaller than 4 cm. Gastrocnemius action potentials were more likely detected for greater inter-electrode distances and their amplitude increased steeply up to 5 cm inter-electrode distance. These results suggest that reducing inter-electrode distance excessively may result in the detection of surface EMGs insensitive to gastrocnemius activity without substantial attenuation of soleus crosstalk."],["dc.identifier.doi","10.1038/s41598-017-13369-1"],["dc.identifier.pmid","29038435"],["dc.identifier.purl","https://resolver.sub.uni-goettingen.de/purl?gs-1/14811"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/59031"],["dc.language.iso","en"],["dc.notes.intern","Merged from goescholar"],["dc.relation.issn","2045-2322"],["dc.rights","CC BY 4.0"],["dc.rights.uri","https://creativecommons.org/licenses/by/4.0"],["dc.subject.ddc","610"],["dc.title","Specificity of surface EMG recordings for gastrocnemius during upright standing."],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.version","published_version"],["dspace.entity.type","Publication"]]Details DOI PMID PMC2017Journal Article [["dc.bibliographiccitation.artnumber","421"],["dc.bibliographiccitation.journal","Frontiers in Neuroscience"],["dc.bibliographiccitation.volume","11"],["dc.contributor.author","Bergmeister, Konstantin D."],["dc.contributor.author","Vujaklija, Ivan"],["dc.contributor.author","Muceli, Silvia"],["dc.contributor.author","Sturma, Agnes"],["dc.contributor.author","Hruby, Laura A."],["dc.contributor.author","Prahm, Cosima"],["dc.contributor.author","Riedl, Otto"],["dc.contributor.author","Salminger, Stefan"],["dc.contributor.author","Manzano-Szalai, Krisztina"],["dc.contributor.author","Aman, Martin"],["dc.contributor.author","Russold, Michael-Friedrich"],["dc.contributor.author","Hofer, Christian"],["dc.contributor.author","Principe, Jose"],["dc.contributor.author","Farina, Dario"],["dc.contributor.author","Aszmann, Oskar C."],["dc.date.accessioned","2019-07-09T11:44:48Z"],["dc.date.available","2019-07-09T11:44:48Z"],["dc.date.issued","2017"],["dc.description.abstract","Modern robotic hands/upper limbs may replace multiple degrees of freedom of extremity function. However, their intuitive use requires a high number of control signals, which current man-machine interfaces do not provide. Here, we discuss a broadband control interface that combines targeted muscle reinnervation, implantable multichannel electromyographic sensors, and advanced decoding to address the increasing capabilities of modern robotic limbs. With targeted muscle reinnervation, nerves that have lost their targets due to an amputation are surgically transferred to residual stump muscles to increase the number of intuitive prosthetic control signals. This surgery re-establishes a nerve-muscle connection that is used for sensing nerve activity with myoelectric interfaces. Moreover, the nerve transfer determines neurophysiological effects, such as muscular hyper-reinnervation and cortical reafferentation that can be exploited by the myoelectric interface. Modern implantable multichannel EMG sensors provide signals from which it is possible to disentangle the behavior of single motor neurons. Recent studies have shown that the neural drive to muscles can be decoded from these signals and thereby the user’s intention can be reliably estimated. By combining these concepts in chronic implants and embedded electronics, we believe that it is in principle possible to establish a broadband man-machine interface, with specific applications in prosthesis control. This perspective illustrates this concept, based on combining advanced surgical techniques with recording hardware and processing algorithms. Here we describe the scientific evidence for this concept, current state of investigations, challenges, and alternative approaches to improve current prosthetic interfaces."],["dc.identifier.doi","10.3389/fnins.2017.00421"],["dc.identifier.purl","https://resolver.sub.uni-goettingen.de/purl?gs-1/14912"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/59101"],["dc.language.iso","en"],["dc.notes.intern","Merged from goescholar"],["dc.relation","info:eu-repo/grantAgreement/EC/FP7/267888/EU//DEMOVE"],["dc.relation.issn","1662-453X"],["dc.rights","CC BY 4.0"],["dc.rights.uri","https://creativecommons.org/licenses/by/4.0"],["dc.subject.ddc","610"],["dc.title","Broadband Prosthetic Interfaces: Combining Nerve Transfers and Implantable Multichannel EMG Technology to Decode Spinal Motor Neuron Activity"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.version","published_version"],["dspace.entity.type","Publication"]]Details DOI