Options
Dosen, Strahinja
Loading...
Preferred name
Dosen, Strahinja
Official Name
Dosen, Strahinja
Alternative Name
Dosen, S.
Došen, Strahinja
Došen, S.
Main Affiliation
Now showing 1 - 10 of 39
2015Journal Article [["dc.bibliographiccitation.artnumber","55"],["dc.bibliographiccitation.issue","1"],["dc.bibliographiccitation.journal","Journal of NeuroEngineering and Rehabilitation"],["dc.bibliographiccitation.volume","12"],["dc.contributor.author","Dosen, Strahinja"],["dc.contributor.author","Markovic, Marko"],["dc.contributor.author","Somer, Kelef"],["dc.contributor.author","Graimann, Bernhard"],["dc.contributor.author","Farina, Dario"],["dc.date.accessioned","2019-07-09T11:41:46Z"],["dc.date.available","2019-07-09T11:41:46Z"],["dc.date.issued","2015"],["dc.description.abstract","Background Active hand prostheses controlled using electromyography (EMG) signals have been used for decades to restore the grasping function, lost after an amputation. Although myocontrol is a simple and intuitive interface, it is also imprecise due to the stochastic nature of the EMG recorded using surface electrodes. Furthermore, the sensory feedback from the prosthesis to the user is still missing. In this study, we present a novel concept to close the loop in myoelectric prostheses. In addition to conveying the grasping force (system output), we provided to the user the online information about the system input (EMG biofeedback). Methods As a proof-of-concept, the EMG biofeedback was transmitted in the current study using a visual interface (ideal condition). Ten able-bodied subjects and two amputees controlled a state-of-the-art myoelectric prosthesis in routine grasping and force steering tasks using EMG and force feedback (novel approach) and force feedback only (classic approach). The outcome measures were the variability of the generated forces and absolute deviation from the target levels in the routine grasping task, and the root mean square tracking error and the number of sudden drops in the force steering task. Results During the routine grasping, the novel method when used by able-bodied subjects decreased twofold the force dispersion as well as absolute deviations from the target force levels, and also resulted in a more accurate and stable tracking of the reference force profiles during the force steering. Furthermore, the force variability during routine grasping did not increase for the higher target forces with EMG biofeedback. The trend was similar in the two amputees. Conclusions The study demonstrated that the subjects, including the two experienced users of a myoelectric prosthesis, were able to exploit the online EMG biofeedback to observe and modulate the myoelectric signals, generating thereby more consistent commands. This allowed them to control the force predictively (routine grasping) and with a finer resolution (force steering). The future step will be to implement this promising and simple approach using an electrotactile interface. A prosthesis with a reliable response, following faithfully user intentions, would improve the utility during daily-life use and also facilitate the embodiment of the assistive system."],["dc.identifier.doi","10.1186/s12984-015-0047-z"],["dc.identifier.pmid","26088323"],["dc.identifier.purl","https://resolver.sub.uni-goettingen.de/purl?gs-1/12335"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/58507"],["dc.language.iso","en"],["dc.relation","info:eu-repo/grantAgreement/EC/FP7/286208/EU//MYOSENS"],["dc.relation.euproject","MYOSENS"],["dc.rights.access","openAccess"],["dc.rights.holder","Dosen et al."],["dc.title","EMG Biofeedback for online predictive control of grasping force in a myoelectric prosthesis"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dspace.entity.type","Publication"]]Details DOI PMID PMC2017Journal Article [["dc.bibliographiccitation.firstpage","2547"],["dc.bibliographiccitation.issue","8"],["dc.bibliographiccitation.journal","Experimental Brain Research"],["dc.bibliographiccitation.lastpage","2559"],["dc.bibliographiccitation.volume","235"],["dc.contributor.author","De Nunzio, Alessandro Marco"],["dc.contributor.author","Dosen, Strahinja"],["dc.contributor.author","Lemling, Sabrina"],["dc.contributor.author","Markovic, Marko"],["dc.contributor.author","Schweisfurth, Meike Annika"],["dc.contributor.author","Ge, Nan"],["dc.contributor.author","Graimann, Bernhard"],["dc.contributor.author","Falla, Deborah"],["dc.contributor.author","Farina, Dario"],["dc.date.accessioned","2019-07-09T11:44:27Z"],["dc.date.available","2019-07-09T11:44:27Z"],["dc.date.issued","2017"],["dc.description.abstract","Grasping is a complex task routinely performed in an anticipatory (feedforward) manner, where sensory feedback is responsible for learning and updating the internal model of grasp dynamics. This study aims at evaluating whether providing a proportional tactile force feedback during the myoelectric control of a prosthesis facilitates learning a stable internal model of the prosthesis force control. Ten able-bodied subjects controlled a sensorized myoelectric prosthesis performing four blocks of consecutive grasps at three levels of target force (30, 50, and 70%), repeatedly closing the fully opened hand. In the first and third block, the subjects received tactile and visual feedback, respectively, while during the second and fourth block, the feedback was removed. The subjects also performed an additional block with no feedback 1 day after the training (Retest). The median and interquartile range of the generated forces was computed to assess the accuracy and precision of force control. The results demonstrated that the feedback was indeed an effective instrument for the training of prosthesis control. After the training, the subjects were still able to accurately generate the desired force for the low and medium target (30 and 50% of maximum force available in a prosthesis), despite the feedback being removed within the session and during the retest (low target force). However, the training was substantially less successful for high forces (70% of prosthesis maximum force), where subjects exhibited a substantial loss of accuracy as soon as the feedback was removed. The precision of control decreased with higher forces and it was consistent across conditions, determined by an intrinsic variability of repeated myoelectric grasping. This study demonstrated that the subject could rely on the tactile feedback to adjust the motor command to the prosthesis across trials. The subjects adjusted the mean level of muscle activation (accuracy), whereas the precision could not be modulated as it depends on the intrinsic myoelectric variability. They were also able to maintain the feedforward command even after the feedback was removed, demonstrating thereby a stable learning, but the retention depended on the level of the target force. This is an important insight into the role of feedback as an instrument for learning of anticipatory prosthesis force control."],["dc.identifier.doi","10.1007/s00221-017-4991-7"],["dc.identifier.pmid","28550423"],["dc.identifier.purl","https://resolver.sub.uni-goettingen.de/purl?gs-1/14765"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/59015"],["dc.notes.intern","Merged from goescholar"],["dc.rights","CC BY 4.0"],["dc.rights.uri","https://creativecommons.org/licenses/by/4.0"],["dc.title","Tactile feedback is an effective instrument for the training of grasping with a prosthesis at low- and medium-force levels"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dspace.entity.type","Publication"]]Details DOI PMID PMC2014Journal Article [["dc.bibliographiccitation.artnumber","120357"],["dc.bibliographiccitation.journal","Computational and Mathematical Methods in Medicine"],["dc.contributor.author","Jorgovanovic, Nikola"],["dc.contributor.author","Dosen, Strahinja"],["dc.contributor.author","Djozic, Damir J."],["dc.contributor.author","Krajoski, Goran"],["dc.contributor.author","Farina, Dario"],["dc.date.accessioned","2018-11-07T09:46:47Z"],["dc.date.available","2018-11-07T09:46:47Z"],["dc.date.issued","2014"],["dc.description.abstract","Closing the control loop by providing somatosensory feedback to the user of a prosthesis is a well-known, long standing challenge in the field of prosthetics. Various approaches have been investigated for feedback restoration, ranging from direct neural stimulation to noninvasive sensory substitution methods. Although there are many studies presenting closed-loop systems, only a few of them objectively evaluated the closed-loop performance, mostly using vibrotactile stimulation. Importantly, the conclusions about the utility of the feedback were partly contradictory. The goal of the current study was to systematically investigate the capability of human subjects to control grasping force in closed loop using electrotactile feedback. We have developed a realistic experimental setup for virtual grasping, which operated in real time, included a set of real life objects, as well as a graphical and dynamical model of the prosthesis. We have used the setup to test 10 healthy, able bodied subjects to investigate the role of training, feedback and feedforward control, robustness of the closed loop, and the ability of the human subjects to generalize the control to previously \"unseen\" objects. Overall, the outcomes of this study are very optimistic with regard to the benefits of feedback and reveal various, practically relevant, aspects of closed-loop control."],["dc.description.sponsorship","Open-Access-Publikationsfonds 2014"],["dc.identifier.doi","10.1155/2014/120357"],["dc.identifier.isi","000330402200001"],["dc.identifier.purl","https://resolver.sub.uni-goettingen.de/purl?gs-1/9756"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/34964"],["dc.notes.intern","Merged from goescholar"],["dc.notes.status","zu prĂĽfen"],["dc.notes.submitter","Najko"],["dc.publisher","Hindawi Publishing Corporation"],["dc.relation.issn","1748-6718"],["dc.relation.issn","1748-670X"],["dc.rights","CC BY 3.0"],["dc.rights.uri","https://creativecommons.org/licenses/by/3.0"],["dc.title","Virtual Grasping: Closed-Loop Force Control Using Electrotactile Feedback"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.status","published"],["dc.type.version","published_version"],["dspace.entity.type","Publication"]]Details DOI WOS2014Journal Article [["dc.bibliographiccitation.firstpage","290"],["dc.bibliographiccitation.issue","2"],["dc.bibliographiccitation.journal","IEEE Transactions on Neural Systems and Rehabilitation Engineering"],["dc.bibliographiccitation.lastpage","301"],["dc.bibliographiccitation.volume","22"],["dc.contributor.author","D'Alonzo, Marco"],["dc.contributor.author","Dosen, Strahinja"],["dc.contributor.author","Cipriani, Christian"],["dc.contributor.author","Farina, Dario"],["dc.date.accessioned","2018-11-07T09:42:44Z"],["dc.date.available","2018-11-07T09:42:44Z"],["dc.date.issued","2014"],["dc.description.abstract","Electro- or vibro-tactile stimulations were used in the past to provide sensory information in many different applications ranging from human manual control to prosthetics. The two modalities were used separately in the past, and we hypothesized that a hybrid vibro-electrotactile (HyVE) stimulation could provide two afferent streams that are independently perceived by a subject, although delivered in parallel and through the same skin location. We conducted psychophysical experiments where healthy subjects were asked to recognize the intensities of electro- and vibro-tactile stimuli during hybrid and single modality stimulations. The results demonstrated that the subjects were able to discriminate the features of the two modalities within the hybrid stimulus, and that the cross-modality interaction was limited enough to allow better transmission of discrete information (messages) using hybrid versus single modality coding. The percentages of successful recognitions (mean +/- standard deviation) for nine messages were 56 +/- 11% and 72 +/- 8% for two hybrid coding schemes, compared to 29 +/- 7% for vibrotactile and 44 +/- 4% for electrotactile coding. The HyVE can be therefore an attractive solution in numerous application for providing sensory feedback in prostheses and rehabilitation, and it could be used to increase the resolution of a single variable or to simultaneously feedback two different variables."],["dc.identifier.doi","10.1109/TNSRE.2013.2266482"],["dc.identifier.isi","000342078300010"],["dc.identifier.pmid","23782817"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/34023"],["dc.notes.status","zu prĂĽfen"],["dc.notes.submitter","Najko"],["dc.publisher","Ieee-inst Electrical Electronics Engineers Inc"],["dc.relation.issn","1558-0210"],["dc.relation.issn","1534-4320"],["dc.title","HyVE: Hybrid Vibro-Electrotactile Stimulation for Sensory Feedback and Substitution in Rehabilitation"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.status","published"],["dspace.entity.type","Publication"]]Details DOI PMID PMC WOS2014Journal Article [["dc.bibliographiccitation.firstpage","181"],["dc.bibliographiccitation.issue","2"],["dc.bibliographiccitation.journal","IEEE Transactions on Haptics"],["dc.bibliographiccitation.lastpage","190"],["dc.bibliographiccitation.volume","7"],["dc.contributor.author","D'Alonzo, Marco"],["dc.contributor.author","Dosen, Strahinja"],["dc.contributor.author","Cipriani, Christian"],["dc.contributor.author","Farina, Dario"],["dc.date.accessioned","2018-11-07T09:41:31Z"],["dc.date.available","2018-11-07T09:41:31Z"],["dc.date.issued","2014"],["dc.description.abstract","An important reason for the abandonment of commercial actuated hand prostheses by the users is the lack of sensory feedback. Wearable afferent interfaces capable of providing electro- or vibro-tactile stimulation have high potential to restore the missing tactile and/or proprioceptive information to the user. By definition, these devices can elicit single modality (i.e., either vibrotactile or electrotactile) substitute sensations. In a recent research we have presented a novel approach comprising hybrid vibro-electrotactile (HyVE) combined stimulation, in order to provide multimodal sensory feedback. An important advantage of this approach is in the size of the design: the HyVE interface is much more compact than two separated single-modality interfaces, since electro- and vibro-tactile stimulators are placed one on top of the other. The HyVE approach has been previously tested in healthy subjects and has shown to provide a range of hybrid stimuli that could be properly discriminated. However, this approach has never been assessed as a method to provide multi-channel stimuli, i.e., stimuli from a variety of stimulators, mapping information from a multitude of sensors on a prosthesis. In this study, the ability of ten healthy subjects to discriminate stimuli and patterns of stimuli from four different five-channel interfaces applied on their forearms was evaluated. We showed that multiple HyVE units could be used to provide multi-channel sensory information with equivalent performance (similar to 95 percent for single stimuli and similar to 80 percent for pattern) to single modality interfaces (vibro- or electro-tactile) larger in size and with better performance than vibrotactile interfaces (i.e., 73 percent for single stimuli and 69 percent for pattern) with the same size. These results are promising in relation to the current availability of multifunctional prostheses with multiple sensors."],["dc.identifier.doi","10.1109/TOH.2013.52"],["dc.identifier.isi","000338514200009"],["dc.identifier.pmid","24968382"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/33751"],["dc.notes.status","zu prĂĽfen"],["dc.notes.submitter","Najko"],["dc.publisher","Ieee Computer Soc"],["dc.relation.issn","2329-4051"],["dc.relation.issn","1939-1412"],["dc.title","HyVE-Hybrid Vibro-Electrotactile Stimulation-Is an Efficient Approach to Multi-Channel Sensory Feedback"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.status","published"],["dspace.entity.type","Publication"]]Details DOI PMID PMC WOS2020Journal Article [["dc.bibliographiccitation.firstpage","645"],["dc.bibliographiccitation.issue","3"],["dc.bibliographiccitation.journal","IEEE Transactions on Haptics"],["dc.bibliographiccitation.lastpage","654"],["dc.bibliographiccitation.volume","13"],["dc.contributor.author","Wilke, Meike A."],["dc.contributor.author","Hartmann, Cornelia"],["dc.contributor.author","Schimpf, Felix"],["dc.contributor.author","Farina, Dario"],["dc.contributor.author","Dosen, Strahinja"],["dc.date.accessioned","2021-04-14T08:25:30Z"],["dc.date.available","2021-04-14T08:25:30Z"],["dc.date.issued","2020"],["dc.identifier.doi","10.1109/TOH.2019.2961652"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/81647"],["dc.notes.intern","DOI Import GROB-399"],["dc.relation.eissn","2329-4051"],["dc.relation.eissn","2334-0134"],["dc.relation.issn","1939-1412"],["dc.title","The Interaction Between Feedback Type and Learning in Routine Grasping With Myoelectric Prostheses"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dspace.entity.type","Publication"]]Details DOI2019Journal Article [["dc.bibliographiccitation.issue","1"],["dc.bibliographiccitation.journal","Journal of NeuroEngineering and Rehabilitation"],["dc.bibliographiccitation.volume","16"],["dc.contributor.author","Wilke, Meike Annika"],["dc.contributor.author","Niethammer, Christian"],["dc.contributor.author","Meyer, Britta"],["dc.contributor.author","Farina, Dario"],["dc.contributor.author","Dosen, Strahinja"],["dc.date.accessioned","2020-12-10T18:39:01Z"],["dc.date.available","2020-12-10T18:39:01Z"],["dc.date.issued","2019"],["dc.identifier.doi","10.1186/s12984-019-0622-9"],["dc.identifier.eissn","1743-0003"],["dc.identifier.purl","https://resolver.sub.uni-goettingen.de/purl?gs-1/17235"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/77512"],["dc.language.iso","en"],["dc.notes.intern","DOI Import GROB-354"],["dc.notes.intern","Merged from goescholar"],["dc.rights","CC BY 4.0"],["dc.rights.uri","https://creativecommons.org/licenses/by/4.0"],["dc.title","Psychometric characterization of incidental feedback sources during grasping with a hand prosthesis"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.version","published_version"],["dspace.entity.type","Publication"]]Details DOI2017Journal Article [["dc.bibliographiccitation.firstpage","2133"],["dc.bibliographiccitation.issue","11"],["dc.bibliographiccitation.journal","IEEE Transactions on Neural Systems and Rehabilitation Engineering"],["dc.bibliographiccitation.lastpage","2145"],["dc.bibliographiccitation.volume","25"],["dc.contributor.author","Strbac, Matija"],["dc.contributor.author","Isakovic, Milica"],["dc.contributor.author","Belic, Minja"],["dc.contributor.author","Popovic, Igor"],["dc.contributor.author","Simanic, Igor"],["dc.contributor.author","Farina, Dario"],["dc.contributor.author","Keller, Thierry"],["dc.contributor.author","Dosen, Strahinja"],["dc.date.accessioned","2020-12-10T18:26:21Z"],["dc.date.available","2020-12-10T18:26:21Z"],["dc.date.issued","2017"],["dc.identifier.doi","10.1109/TNSRE.2017.2712287"],["dc.identifier.eissn","1558-0210"],["dc.identifier.issn","1534-4320"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/76052"],["dc.notes.intern","DOI Import GROB-354"],["dc.title","Short- and Long-Term Learning of Feedforward Control of a Myoelectric Prosthesis with Sensory Feedback by Amputees"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dspace.entity.type","Publication"]]Details DOI2015Journal Article [["dc.bibliographiccitation.firstpage","267"],["dc.bibliographiccitation.issue","2"],["dc.bibliographiccitation.journal","IEEE Transactions on Neural Systems and Rehabilitation Engineering"],["dc.bibliographiccitation.lastpage","276"],["dc.bibliographiccitation.volume","23"],["dc.contributor.author","Dosen, Strahinja"],["dc.contributor.author","Markovic, Marko"],["dc.contributor.author","Hartmann, Cornelia"],["dc.contributor.author","Farina, Dario"],["dc.date.accessioned","2018-11-07T10:00:17Z"],["dc.date.available","2018-11-07T10:00:17Z"],["dc.date.issued","2015"],["dc.description.abstract","Closing the control loop by providing sensory feedback to the user of a prosthesis is an important challenge, with major impact on the future of prosthetics. Developing and comparing closed-loop systems is a difficult task, since there are many different methods and technologies that can be used to implement each component of the system. Here, we present a test bench developed in Matlab Simulink for configuring and testing the closed-loop human control system in standardized settings. The framework comprises a set of connected generic blocks with normalized inputs and outputs, which can be customized by selecting specific implementations from a library of predefined components. The framework is modular and extensible and it can be used to configure, compare and test different closed-loop system prototypes, thereby guiding the development towards an optimal system configuration. The use of the test bench was demonstrated by investigating two important aspects of closed-loop control: performance of different electrotactile feedback interfaces (spatial versus intensity coding) during a pendulum stabilization task and feedforward methods (joystick versus myocontrol) for force control. The first experiment demonstrated that in the case of trained subjects the intensity coding might be superior to spatial coding. In the second experiment, the control of force was rather poor even with a stable and precise control interface (joystick), demonstrating that inherent characteristics of the prosthesis can be an important limiting factor when considering the overall effectiveness of the closed-loop control. The presented test bench is an important instrument for investigating different aspects of human manual control with sensory feedback."],["dc.identifier.doi","10.1109/TNSRE.2014.2371238"],["dc.identifier.isi","000351365100013"],["dc.identifier.pmid","25420268"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/37769"],["dc.notes.status","zu prĂĽfen"],["dc.notes.submitter","Najko"],["dc.publisher","Ieee-inst Electrical Electronics Engineers Inc"],["dc.relation.issn","1558-0210"],["dc.relation.issn","1534-4320"],["dc.title","Sensory Feedback in Prosthetics: A Standardized Test Bench for Closed-Loop Control"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.status","published"],["dspace.entity.type","Publication"]]Details DOI PMID PMC WOS2014Review [["dc.bibliographiccitation.firstpage","1"],["dc.bibliographiccitation.journal","Frontiers in Neurorobotics"],["dc.bibliographiccitation.lastpage","17"],["dc.bibliographiccitation.volume","8"],["dc.contributor.author","Castellini, Claudio"],["dc.contributor.author","Artemiadis, Panagiotis"],["dc.contributor.author","Wininger, Michael"],["dc.contributor.author","Ajoudani, Arash"],["dc.contributor.author","Alimusaj, Merkur"],["dc.contributor.author","Bicchi, Antonio"],["dc.contributor.author","Caputo, Barbara"],["dc.contributor.author","Craelius, William"],["dc.contributor.author","Dosen, Strahinja"],["dc.contributor.author","Englehart, Kevin B."],["dc.contributor.author","Farina, Dario"],["dc.contributor.author","Gijsberts, Arjan"],["dc.contributor.author","Godfrey, Sasha B."],["dc.contributor.author","Hargrove, Levi"],["dc.contributor.author","Ison, Mark"],["dc.contributor.author","Kuiken, Todd"],["dc.contributor.author","Markovic, Marko"],["dc.contributor.author","Pilarski, Patrick M."],["dc.contributor.author","Rupp, Ruediger"],["dc.contributor.author","Scheme, Erik"],["dc.date.accessioned","2018-11-07T09:36:33Z"],["dc.date.available","2018-11-07T09:36:33Z"],["dc.date.issued","2014"],["dc.description.abstract","One of the hottest topics in rehabilitation robotics is that of proper control of prosthetic devices. Despite decades of research, the state of the art is dramatically behind the expectations. To shed light on this issue, in June, 2013 the first international workshop on Present and future of non-invasive peripheral nervous system (PNS)-Machine Interfaces (MI; PMI) was convened, hosted by the International Conference on Rehabilitation Robotics. The keyword PMI has been selected to denote human-machine interfaces targeted at the limb-deficient, mainly upper-limb amputees, dealing with signals gathered from the PNS in a non-invasive way, that is, from the surface of the residuum. The workshop was intended to provide an overview of the state of the art and future perspectives of such interfaces; this paper represents is a collection of opinions expressed by each and every researcher/group involved in it."],["dc.identifier.doi","10.3389/fnbot.2014.00022"],["dc.identifier.isi","000348815300001"],["dc.identifier.purl","https://resolver.sub.uni-goettingen.de/purl?gs-1/12193"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/32642"],["dc.language.iso","en"],["dc.notes.intern","Merged from goescholar"],["dc.notes.status","zu prĂĽfen"],["dc.notes.submitter","Najko"],["dc.publisher","Frontiers Media S.A."],["dc.relation.eissn","1662-5218"],["dc.relation.issn","1662-5218"],["dc.rights","CC BY 3.0"],["dc.rights.uri","https://creativecommons.org/licenses/by/3.0"],["dc.title","Proceedings of the first workshop on Peripheral Machine Interfaces: going beyond traditional surface electromyography"],["dc.type","review"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.status","published"],["dc.type.version","published_version"],["dspace.entity.type","Publication"]]Details DOI WOS