Options
Hahn, Wolfram
Loading...
Preferred name
Hahn, Wolfram
Official Name
Hahn, Wolfram
Alternative Name
Hahn, W.
Main Affiliation
Now showing 1 - 8 of 8
2022Journal Article Erratum [["dc.bibliographiccitation.journal","Clinical Oral Investigations"],["dc.contributor.author","Wiechens, Bernhard"],["dc.contributor.author","Brockmeyer, Phillipp"],["dc.contributor.author","Erfurth‑Jach, Teresa"],["dc.contributor.author","Hahn, Wolfram"],["dc.date.accessioned","2022-07-01T07:35:36Z"],["dc.date.available","2022-07-01T07:35:36Z"],["dc.date.issued","2022"],["dc.identifier.doi","10.1007/s00784-022-04575-x"],["dc.identifier.pii","4575"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/112214"],["dc.language.iso","en"],["dc.notes.intern","DOI-Import GROB-581"],["dc.relation.eissn","1436-3771"],["dc.relation.iserratumof","/handle/2/112213"],["dc.rights.uri","https://creativecommons.org/licenses/by/4.0"],["dc.title","Correction to: Force delivery modification of removable thermoplastic appliances using Hilliard precision thermopliers for tipping an upper central incisor"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.subtype","erratum_ja"],["dspace.entity.type","Publication"]]Details DOI2014Journal Article [["dc.bibliographiccitation.firstpage","1321"],["dc.bibliographiccitation.issue","11"],["dc.bibliographiccitation.journal","Clinical Oral Implants Research"],["dc.bibliographiccitation.lastpage","1327"],["dc.bibliographiccitation.volume","26"],["dc.contributor.author","Brockmeyer, Phillipp"],["dc.contributor.author","Lange, Katharina"],["dc.contributor.author","Hahn, Wolfram"],["dc.contributor.author","Schliephake, Henning"],["dc.contributor.author","Matthias Gruber, Rudolf"],["dc.date.accessioned","2021-06-01T10:47:12Z"],["dc.date.available","2021-06-01T10:47:12Z"],["dc.date.issued","2014"],["dc.identifier.doi","10.1111/clr.12457"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/85520"],["dc.language.iso","en"],["dc.notes.intern","DOI-Import GROB-425"],["dc.relation.issn","0905-7161"],["dc.title","Increase of homogenous new bone formation using osteoinductive factor rhGDF-5 during sinus floor augmentation in Goettingen Minipigs"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dspace.entity.type","Publication"]]Details DOI2022Journal Article [["dc.bibliographiccitation.issue","1"],["dc.bibliographiccitation.journal","BMC Oral Health"],["dc.bibliographiccitation.volume","22"],["dc.contributor.author","Brockmeyer, Phillipp"],["dc.contributor.author","Wiechens, Bernhard"],["dc.contributor.author","Sevinc, Tayhan"],["dc.contributor.author","Schliephake, Henning"],["dc.contributor.author","Hahn, Wolfram"],["dc.date.accessioned","2022-09-01T09:50:55Z"],["dc.date.available","2022-09-01T09:50:55Z"],["dc.date.issued","2022"],["dc.description.abstract","Abstract\n \n Background\n To test the hypothesis that cephalometric parameters in two-dimensional routine dental radiographs correlate with the bone volume of intraoral bone donor sites.\n \n \n Methods\n One-hundred and eight radiographs [36 panoramic radiographs (PRs), 36 lateral cephalometric radiographs (LCRs), and 36 cone-beam computed tomography scans (CBCT)] of 36 patients (all three imaging techniques applied according to the needs of treatment planning), were analyzed individually. Cephalometric parameters (PR and LCR) were correlated with the bone volume measurement in three-dimensional CBCT scans in three intraoral donor sites (chin, mandibular retromolar region, and zygomatic alveolar crest).\n \n \n Results\n \n The mean bone volumes measured for the chin were (3.10 ± 1.11 cm³ SD), the mandibular retromolar region (1.66 ± 0.54 cm³ SD), and the zygomatic alveolar crest (0.17 ± 0.04 cm³ SD). Cephalometric parameters were significantly correlated (all\n p\n -values < 0.05) with the bone volume in the chin and the mandibular retromolar region. The bone volume of the zygomatic alveolar crest exhibited no correlations (\n p\n > 0.05) with cephalometric parameters. However, it was significantly correlated (\n p\n < 0.01) with the mandibular retromolar bone volume. No gender-specific differences (\n p\n > 0.05) were observed concerning bone volumes in all bone harvesting regions. Nevertheless, the male population’s interforaminal distance in the chin region was significantly higher (\n p\n = 0.001).\n \n \n \n Conclusions\n PRs and LCRs can be used at the initial stage of peri-implant augmentation planning to deduce conclusions about the bone volume in different intraoral bone donor sites. It can help describe indications and justify additional diagnostic options, such as three-dimensional radiologic techniques."],["dc.identifier.doi","10.1186/s12903-022-02344-6"],["dc.identifier.pii","2344"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/113837"],["dc.language.iso","en"],["dc.notes.intern","DOI-Import GROB-597"],["dc.relation.eissn","1472-6831"],["dc.rights.uri","https://creativecommons.org/licenses/by/4.0"],["dc.title","Informational content of two-dimensional panoramic radiographs and lateral cephalometric radiographs with respect to the bone volume of intraoral donor regions considering CBCT imaging"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dspace.entity.type","Publication"]]Details DOI2017-01Journal Article [["dc.bibliographiccitation.firstpage","20"],["dc.bibliographiccitation.issue","1"],["dc.bibliographiccitation.journal","Oral surgery, oral medicine, oral pathology and oral radiology"],["dc.bibliographiccitation.lastpage","28"],["dc.bibliographiccitation.volume","123"],["dc.contributor.author","Kauffmann, Philipp"],["dc.contributor.author","Hahn, Wolfram"],["dc.contributor.author","Sievers, Niklas"],["dc.contributor.author","Troeltzsch, Markus"],["dc.contributor.author","Hohloch, Karin"],["dc.contributor.author","Brockmeyer, Phillipp"],["dc.contributor.author","Cordesmeyer, Robert"],["dc.contributor.author","Schliephake, Henning"],["dc.contributor.author","Gruber, Rudolf Matthias"],["dc.date.accessioned","2018-06-25T07:43:01Z"],["dc.date.available","2018-06-25T07:43:01Z"],["dc.date.issued","2017-01"],["dc.description.abstract","We compared the intraindividual effects of increasing zoledronic acid (ZA) concentrations on osteoblast-like cells with different embryologic origins."],["dc.fs.pkfprnr","2489"],["dc.identifier.doi","10.1016/j.oooo.2016.08.010"],["dc.identifier.fs","626267"],["dc.identifier.pmid","27720655"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/15133"],["dc.language.iso","en"],["dc.notes.status","final"],["dc.relation.eissn","2212-4411"],["dc.title","Osteoblast-like cells with different embryologic origins behave differently in increasing zoledronic acid concentrations: a pilot study in pigs"],["dc.type","journal_article"],["dc.type.internalPublication","unknown"],["dspace.entity.type","Publication"]]Details DOI PMID PMC2022Journal Article [["dc.bibliographiccitation.artnumber","cre2.639"],["dc.bibliographiccitation.journal","Clinical and Experimental Dental Research"],["dc.contributor.author","Wiechens, Bernhard"],["dc.contributor.author","Brockmeyer, Phillipp"],["dc.contributor.author","Sevinc, Tayhan"],["dc.contributor.author","Hoene, Georg"],["dc.contributor.author","Schliephake, Henning"],["dc.contributor.author","Hahn, Wolfram"],["dc.date.accessioned","2022-09-01T09:49:37Z"],["dc.date.available","2022-09-01T09:49:37Z"],["dc.date.issued","2022"],["dc.identifier.doi","10.1002/cre2.639"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/113481"],["dc.language.iso","en"],["dc.notes.intern","DOI-Import GROB-597"],["dc.relation.eissn","2057-4347"],["dc.relation.issn","2057-4347"],["dc.rights.uri","http://creativecommons.org/licenses/by/4.0/"],["dc.title","Diagnostic value of routine dental radiographs for predicting the mandibular canal localization validated by cone‐beam computed tomogram measurements"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dspace.entity.type","Publication"]]Details DOI2022Journal Article [["dc.bibliographiccitation.journal","Clinical Oral Investigations"],["dc.contributor.author","Wiechens, Bernhard"],["dc.contributor.author","Brockmeyer, Phillipp"],["dc.contributor.author","Erfurth-Jach, Teresa"],["dc.contributor.author","Hahn, Wolfram"],["dc.date.accessioned","2022-07-01T07:35:36Z"],["dc.date.available","2022-07-01T07:35:36Z"],["dc.date.issued","2022"],["dc.description.abstract","Abstract Objectives To evaluate the force delivered by removable thermoplastic appliances (RTAs, aligners), altered with Hilliard precision thermopliers, on an upper central incisor to tip it in the palatal and vestibular directions. Materials and methods A total of 10 aligners made from Ideal Clear® (polyethylene terephthalate glycol copolyester, PET-G) with a thickness of 1 mm were used in force analysis. Different-sized spot-thermoformed protuberances (bumps) were generated by activating the thermoplier (thin and thick) up to 30°, 60° and 90° in the centre of the palatal and vestibular surfaces of the aligner in 15° steps. The tipping (Fx) and intrusive (Fz) force components were measured on the isolated upper central incisor as part of a standardized resin model, with or without vertical loading by a weight equivalent. Results Thermoplier activation at 30°, 60° and 90° resulted in different bump heights. The analysis revealed significantly higher Fx and Fz values with increasing bump heights for every activation step in all cases ( p < 0.0001, respectively). Overall, the values of the Fx force component were higher than those observed for Fz. Significant differences between the palatal and vestibular tipping procedures were found depending on the resulting force components when the thin thermoplier was used; in contrast, the thick thermoplier resulted in a larger dispersion of the force magnitudes. Conclusions Aligners modified with Hilliard precision thermopliers showed altered biomechanical parameters. This approach could be an option for treatment modification. Clinical relevance The instrumental examination provided informative results for daily practice, as activation, force dosage and different force values under chewing pressure can be estimated more precisely based on the determined force levels."],["dc.identifier.doi","10.1007/s00784-022-04560-4"],["dc.identifier.pii","4560"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/112213"],["dc.language.iso","en"],["dc.notes.intern","DOI-Import GROB-581"],["dc.relation.eissn","1436-3771"],["dc.relation.haserratum","/handle/2/112214"],["dc.rights.uri","https://creativecommons.org/licenses/by/4.0"],["dc.title","Force delivery modification of removable thermoplastic appliances using Hilliard precision thermopliers for tipping an upper central incisor"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dspace.entity.type","Publication"]]Details DOI2015Journal Article [["dc.bibliographiccitation.firstpage","301"],["dc.bibliographiccitation.issue","3"],["dc.bibliographiccitation.journal","Oral and Maxillofacial Surgery"],["dc.bibliographiccitation.lastpage","307"],["dc.bibliographiccitation.volume","19"],["dc.contributor.author","Brockmeyer, Phillipp"],["dc.contributor.author","Hahn, Wolfram"],["dc.contributor.author","Fenge, Stefan"],["dc.contributor.author","Moser, Norman"],["dc.contributor.author","Schliephake, Henning"],["dc.contributor.author","Gruber, Rudolf Matthias"],["dc.date.accessioned","2021-06-01T10:49:17Z"],["dc.date.available","2021-06-01T10:49:17Z"],["dc.date.issued","2015"],["dc.identifier.doi","10.1007/s10006-015-0499-0"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/86229"],["dc.language.iso","en"],["dc.notes.intern","DOI-Import GROB-425"],["dc.relation.eissn","1865-1569"],["dc.relation.issn","1865-1550"],["dc.title","Reduced somatosensory impairment by piezosurgery during orthognathic surgery of the mandible"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dspace.entity.type","Publication"]]Details DOI2017-08-28Journal Article [["dc.bibliographiccitation.firstpage","28"],["dc.bibliographiccitation.issue","1"],["dc.bibliographiccitation.journal","Progress in Orthodontics"],["dc.bibliographiccitation.volume","18"],["dc.contributor.author","Brockmeyer, Phillipp"],["dc.contributor.author","Kramer, Katharina"],["dc.contributor.author","Böhrnsen, Florian"],["dc.contributor.author","Gruber, Rudolf Matthias"],["dc.contributor.author","Batschkus, Sarah"],["dc.contributor.author","Rödig, Tina"],["dc.contributor.author","Hahn, Wolfram"],["dc.date.accessioned","2018-06-25T08:18:06Z"],["dc.date.available","2018-06-25T08:18:06Z"],["dc.date.issued","2017-08-28"],["dc.description.abstract","The present study aimed to evaluate the force delivery of removable thermoplastic appliances (RTAs), modified by different sized incisal cuts, during tipping of a maxillary central incisor in palatal and vestibular direction."],["dc.fs.pkfprnr","43706"],["dc.identifier.doi","10.1186/s40510-017-0183-z"],["dc.identifier.fs","628547"],["dc.identifier.pmid","28845511"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/15137"],["dc.language.iso","en"],["dc.notes.status","zu prüfen"],["dc.relation.eissn","2196-1042"],["dc.title","Removable thermoplastic appliances modified by incisal cuts show altered biomechanical properties during tipping of a maxillary central incisor"],["dc.type","journal_article"],["dc.type.internalPublication","unknown"],["dspace.entity.type","Publication"]]Details DOI PMID PMC