Options
Wagner, Daniela Melanie
Loading...
Preferred name
Wagner, Daniela Melanie
Official Name
Wagner, Daniela Melanie
Alternative Name
Wagner, Daniela M.
Wagner, D. M.
Wagner, Daniela
Wagner, D.
Main Affiliation
Now showing 1 - 1 of 1
2009Journal Article [["dc.bibliographiccitation.firstpage","455"],["dc.bibliographiccitation.issue","3"],["dc.bibliographiccitation.journal","Radiotherapy and Oncology"],["dc.bibliographiccitation.lastpage","460"],["dc.bibliographiccitation.volume","91"],["dc.contributor.author","Vorwerk, Hilke"],["dc.contributor.author","Beckmann, Gabriele"],["dc.contributor.author","Bremer, Michael"],["dc.contributor.author","Degen, Maria"],["dc.contributor.author","Dietl, Barbara"],["dc.contributor.author","Fietkau, Rainer"],["dc.contributor.author","Gsaenger, Tammo"],["dc.contributor.author","Hermann, Robert Michael"],["dc.contributor.author","Herrmann, Markus Karl Alfred"],["dc.contributor.author","Hoeller, Ulrike"],["dc.contributor.author","van Kampen, Michael"],["dc.contributor.author","Koerber, Wolfgang"],["dc.contributor.author","Maier, Burkhard"],["dc.contributor.author","Martin, Thomas"],["dc.contributor.author","Metz, Michael"],["dc.contributor.author","Richter, Ronald"],["dc.contributor.author","Siekmeyer, Birgit"],["dc.contributor.author","Steder, Martin"],["dc.contributor.author","Wagner, Daniela"],["dc.contributor.author","Hess, Clemens Friedrich"],["dc.contributor.author","Weiss, Elisabeth"],["dc.contributor.author","Christiansen, Hans"],["dc.date.accessioned","2018-11-07T08:29:37Z"],["dc.date.available","2018-11-07T08:29:37Z"],["dc.date.issued","2009"],["dc.description.abstract","Purpose: Differences in the delineation of the gross target volume (GTV) and planning target volume (PTV) in patients with non-small-cell lung cancer are considerable. The focus of this work is on the analysis of observer-related reasons while controlling for other variables. Methods: In three consecutive patients, eighteen physicians from fourteen different departments delineated the GTV and M in CT-slices using a detailed instruction for target delineation. Differences in the volumes, the delineated anatomic lymph node compartments and differences in every delineated pixel of the contoured volumes in the CT-slices (pixel-by-pixel-analysis) were evaluated for different groups: ten radiation oncologists from ten departments (ROs), four haematologic oncologists and chest physicians from four departments (HOs) and five radiation oncologists from one department (RO1D). Results: Agreement (overlap >= 70% of the contoured pixels) for the GTV and PTV delineation was found in 16.3% and 23.7% (ROs), 30.4% and 38.6% (HOs) and 32.8% and 35.9% (RO1D), respectively. Conclusion: A large interobserver variability in the PTV and much more in the GTV delineation were observed in spite of a detailed instruction for delineation. The variability was smallest for group RO1D where due to repeated discussions and uniform teaching a better agreement was achieved. (C) 2009 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 91 (2009) 455-460"],["dc.identifier.doi","10.1016/j.radonc.2009.03.014"],["dc.identifier.isi","000266749200028"],["dc.identifier.pmid","19339069"],["dc.identifier.purl","https://resolver.sub.uni-goettingen.de/purl?gs-1/6276"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/16693"],["dc.notes.intern","Merged from goescholar"],["dc.notes.status","zu prĂĽfen"],["dc.notes.submitter","Najko"],["dc.publisher","Elsevier Ireland Ltd"],["dc.relation.issn","0167-8140"],["dc.rights","Goescholar"],["dc.rights.uri","https://goescholar.uni-goettingen.de/licenses"],["dc.title","The delineation of target volumes for radiotherapy of lung cancer patients"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.status","published"],["dspace.entity.type","Publication"]]Details DOI PMID PMC WOS