Now showing 1 - 2 of 2
  • 2013Journal Article
    [["dc.bibliographiccitation.firstpage","1739"],["dc.bibliographiccitation.issue","10"],["dc.bibliographiccitation.journal","Journal of Biomechanics"],["dc.bibliographiccitation.lastpage","1745"],["dc.bibliographiccitation.volume","46"],["dc.contributor.author","Wachowski, Martin Michael"],["dc.contributor.author","Wagner, Markus"],["dc.contributor.author","Weiland, Jan"],["dc.contributor.author","Doerner, Jochen"],["dc.contributor.author","Raab, Bjoern Werner"],["dc.contributor.author","Dathe, Henning"],["dc.contributor.author","Gezzi, Riccardo"],["dc.contributor.author","Kubein-Meesenburg, Dietmar"],["dc.contributor.author","Naegerl, Hans"],["dc.date.accessioned","2018-11-07T09:23:36Z"],["dc.date.available","2018-11-07T09:23:36Z"],["dc.date.issued","2013"],["dc.description.abstract","We analyze how kinematic properties of C3/C4-segments are modified after total disc arthroplasty (TDA) with PRESTIGE (R) and BRYAN (R) Cervical Discs. The measurements were focused on small ranges of axial rotation (<0.8 degrees) in order to investigate physiologic rotations, which frequently occur in vivo. Eight human segments were stimulated by triangularly varying, axially directed torque. By using a 6D-measuring device with high resolution the response of segmental motion was characterised by the instantaneous helical axis (IHA). Position, direction, and migration rate of the IHA were measured before and after TDA. External parameters: constant axially directed pre-load, constant flexional/extensional and lateral-flexional pre-torque. The applied axial torque and IHA-direction did not run parallel. The IHA-direction was found to be rotated backwards and largely independent of the rotational angle, amount of axial pre-load, size of pre-torque, and TDA. In the intact segments pre-flexion/extension hardly influenced IHA-positions. After TDA, IHA-position was shifted backwards significantly (BRYAN-TDA: approximate to 8 mm; PRESTIGE-TDA: approximate to 6 mm) and in some segments laterally as well. Furthermore it was significantly shifted ventrally by pre-flexion and dorsally by pre-extension. The rate of lateral IHA-migration increased significantly after BRYAN-TDA during rightward or leftward rotations. In conclusion after the TDA the IHA-positions shifted backwards with significant increase in variability of the IHA-positions after the BRYAN-TDA more than in PRESTIGE-TDA. The TDA-procedure altered the segment kinematics considerably. TDA causes additional translations of the vertebrae, which superimpose the kinematics of the adjacent levels. The occurrence of adjacent level disease (ALD) is not excluded after the TDA for kinematical reasons. (C) 2013 Elsevier Ltd. All rights reserved."],["dc.identifier.doi","10.1016/j.jbiomech.2013.03.027"],["dc.identifier.isi","000321422400020"],["dc.identifier.pmid","23659912"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/29619"],["dc.notes.status","zu prĂĽfen"],["dc.notes.submitter","Najko"],["dc.publisher","Elsevier Sci Ltd"],["dc.relation.issn","0021-9290"],["dc.title","Does total disc arthroplasty in C3/C4-segments change the kinematic features of axial rotation?"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.status","published"],["dspace.entity.type","Publication"]]
    Details DOI PMID PMC WOS
  • 2017Journal Article
    [["dc.bibliographiccitation.firstpage","2425"],["dc.bibliographiccitation.issue","9"],["dc.bibliographiccitation.journal","European Spine Journal"],["dc.bibliographiccitation.lastpage","2433"],["dc.bibliographiccitation.volume","26"],["dc.contributor.author","Wachowski, Martin Michael"],["dc.contributor.author","Weiland, Jan"],["dc.contributor.author","Wagner, Markus"],["dc.contributor.author","Gezzi, Riccardo"],["dc.contributor.author","Kubein-Meesenburg, Dietmar"],["dc.contributor.author","Nägerl, Hans"],["dc.date.accessioned","2020-12-10T14:10:50Z"],["dc.date.available","2020-12-10T14:10:50Z"],["dc.date.issued","2017"],["dc.identifier.doi","10.1007/s00586-017-5073-z"],["dc.identifier.eissn","1432-0932"],["dc.identifier.issn","0940-6719"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/70892"],["dc.language.iso","en"],["dc.notes.intern","DOI Import GROB-354"],["dc.title","Kinematics of cervical segments C5/C6 in axial rotation before and after total disc arthroplasty"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dspace.entity.type","Publication"]]
    Details DOI