Options
SIMS study on the surface chemistry of stainless steel AISI 304 cylindrical tensile test samples showing hydrogen embrittlement
ISSN
0925-8388
Date Issued
2011
Author(s)
DOI
10.1016/j.jallcom.2010.12.143
Abstract
The local surface chemistry of a low-Ni austenitic stainless steel AISI type 304 used for tensile testing in hydrogen atmosphere is characterized by secondary ion mass spectrometry (SIMS). A chemical map on cylindrical austenitic stainless steel samples can be obtained even after a tensile test. In an effort to obtain the proper chemical element distribution on the samples, the influence of contamination and sample orientation is discussed. An iron oxide on top of a chromium oxide layer is present and Si segregation at grain boundaries is detected. Oxides are judged to reduce the initial hydrogen attack but to be of minor importance for crack propagation during the embrittlement process. (C) 2011 Elsevier B.V. All rights reserved.