Options
Rödiger, Matthias
Loading...
Preferred name
Rödiger, Matthias
Official Name
Rödiger, Matthias
Alternative Name
Rödiger, M.
Roediger, Matthias
Roediger, M.
Main Affiliation
Now showing 1 - 10 of 36
2018Journal Article [["dc.bibliographiccitation.firstpage","35"],["dc.bibliographiccitation.issue","1"],["dc.bibliographiccitation.journal","The International Journal of Prosthodontics"],["dc.bibliographiccitation.lastpage","42"],["dc.bibliographiccitation.volume","31"],["dc.contributor.author","Rinke, Sven"],["dc.contributor.author","Wehle, Jens"],["dc.contributor.author","Schulz, Xenia"],["dc.contributor.author","Bürgers, Ralf"],["dc.contributor.author","Rödiger, Matthias"],["dc.date.accessioned","2020-12-10T18:37:53Z"],["dc.date.available","2020-12-10T18:37:53Z"],["dc.date.issued","2018"],["dc.identifier.doi","10.11607/ijp.5283"],["dc.identifier.issn","0893-2174"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/77128"],["dc.notes.intern","DOI Import GROB-354"],["dc.title","Prospective Evaluation of Posterior Fixed Zirconia Dental Prostheses: 10-Year Clinical Results"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dspace.entity.type","Publication"]]Details DOI2018Journal Article [["dc.bibliographiccitation.artnumber","2143906"],["dc.bibliographiccitation.firstpage","1"],["dc.bibliographiccitation.journal","BioMed Research International"],["dc.bibliographiccitation.lastpage","8"],["dc.bibliographiccitation.volume","2018"],["dc.contributor.author","Rödiger, Matthias"],["dc.contributor.author","Schneider, Lea"],["dc.contributor.author","Rinke, Sven"],["dc.date.accessioned","2019-07-09T11:45:18Z"],["dc.date.available","2019-07-09T11:45:18Z"],["dc.date.issued","2018"],["dc.description.abstract","This study evaluated the marginal accuracy of CAD/CAM-fabricated crown copings from four different materials within the same processing route. Twenty stone replicas of a metallic master die (prepared upper premolar) were scanned and divided into two groups. Group 1 (𝑛� = 10) was used for a pilot test to determine the design parameters for best marginal accuracy. Group 2 (𝑛� = 10) was used to fabricate 10 specimens from the following materials with one identical CAD/CAM system (GAMMA 202, Wissner GmbH, Goettingen, Germany): A = commercially pure (cp) titanium, B = cobalt-chromium alloy, C = yttria-stabilized zirconia (YSZ), and D = leucite-reinforced glass-ceramics. Copings from group 2 were evaluated for the mean marginal gap size (MeanMG) and average maximum marginal gap size (AMaxMG) with a light microscope in the “as-machined” state. The effect of the material on the marginal accuracy was analyzed by multiple pairwise comparisons (Mann–Whitney, 𝑈�-test, 𝛼� = 0.05, adjusted by Bonferroni-Holmes method). MeanMG values were as follows: A: 46.92 ± 23.12 𝜇�m, B: 48.37 ± 29.72 𝜇�m, C: 68.25 ± 28.54 𝜇�m, and D: 58.73 ± 21.15 𝜇�m. The differences in the MeanMG values proved to be significant for groups A/C (𝑝� = 0.0024), A/D (𝑝� = 0.008), and B/C (𝑝� = 0.0332). AMaxMG values (A: 91.54 ± 23.39 𝜇�m, B: 96.86 ± 24.19 𝜇�m, C: 120.66 ± 32.75 𝜇�m, and D: 100.22 ± 10.83 𝜇�m) revealed no ignificant differences. The material had a significant impact on the marginal accuracy of CAD/CAM-fabricated copings."],["dc.identifier.doi","10.1155/2018/2143906"],["dc.identifier.purl","https://resolver.sub.uni-goettingen.de/purl?gs-1/15103"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/59206"],["dc.language.iso","en"],["dc.notes.intern","Merged from goescholar"],["dc.relation.issn","2314-6141"],["dc.rights","Goescholar"],["dc.rights.uri","https://goescholar.uni-goettingen.de/licenses"],["dc.subject.ddc","610"],["dc.title","Influence of Material Selection on the Marginal Accuracy of CAD/CAM-Fabricated Metal- and All-Ceramic Single Crown Copings"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.version","published_version"],["dspace.entity.type","Publication"]]Details DOI2016Journal Article [["dc.bibliographiccitation.firstpage","1"],["dc.bibliographiccitation.journal","Case Reports in Dentistry"],["dc.bibliographiccitation.lastpage","7"],["dc.bibliographiccitation.volume","2016"],["dc.contributor.author","Rinke, Sven"],["dc.contributor.author","Pabel, Anne-Kathrin"],["dc.contributor.author","Rödiger, Matthias"],["dc.contributor.author","Ziebolz, Dirk"],["dc.date.accessioned","2020-12-10T18:37:40Z"],["dc.date.available","2020-12-10T18:37:40Z"],["dc.date.issued","2016"],["dc.identifier.doi","10.1155/2016/1354186"],["dc.identifier.eissn","2090-6455"],["dc.identifier.issn","2090-6447"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/77060"],["dc.language.iso","en"],["dc.notes.intern","DOI Import GROB-354"],["dc.title","Chairside Fabrication of an All-Ceramic Partial Crown Using a Zirconia-Reinforced Lithium Silicate Ceramic"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dspace.entity.type","Publication"]]Details DOI2010Journal Article [["dc.bibliographiccitation.firstpage","177"],["dc.bibliographiccitation.issue","2-3"],["dc.bibliographiccitation.journal","Journal of Molecular Histology"],["dc.bibliographiccitation.lastpage","184"],["dc.bibliographiccitation.volume","41"],["dc.contributor.author","Roediger, Matthias"],["dc.contributor.author","Miosge, Nicolai"],["dc.contributor.author","Gersdorff, Nikolaus"],["dc.date.accessioned","2018-08-20T11:49:34Z"],["dc.date.available","2018-08-20T11:49:34Z"],["dc.date.issued","2010"],["dc.description.abstract","Laminins are the major glycoproteins present in all basement membranes. Previously, we showed that perlecan is present during human development. Although an overview of mRNA-expression of the laminin beta1 and beta2 chains in various developing fetal organs is already available, a systematic localization of the laminin beta1 and beta2 chains on the protein level during embryonic and fetal human development is missing. Therefore, we studied the immunohistochemical expression and tissue distribution of the laminin beta1 and beta2 chains in various developing embryonic and fetal human organs between gestational weeks 8 and 12. The laminin beta1 chain was ubiquitously expressed in the basement membrane zones of the brain, ganglia, blood vessels, liver, kidney, skin, pancreas, intestine, heart and skeletal system. Furthermore, the laminin beta2 chain was present in the basement membrane zones of the brain, ganglia, skin, heart and skeletal system. The findings of this study support and expand upon the theory that these two laminin chains are important during human development."],["dc.identifier.doi","10.1007/s10735-010-9275-5"],["dc.identifier.pmid","20552257"],["dc.identifier.purl","https://resolver.sub.uni-goettingen.de/purl?gs-1/5016"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/15420"],["dc.language.iso","en"],["dc.notes.intern","Merged from goescholar"],["dc.notes.status","final"],["dc.relation.eissn","1567-2387"],["dc.relation.eissn","1567-2379"],["dc.rights","Goescholar"],["dc.rights.uri","https://goescholar.uni-goettingen.de/licenses"],["dc.title","Tissue distribution of the laminin β1 and β2 chain during embryonic and fetal human development"],["dc.type","journal_article"],["dc.type.internalPublication","unknown"],["dc.type.version","published_version"],["dspace.entity.type","Publication"]]Details DOI PMID PMC2012Journal Article [["dc.bibliographiccitation.firstpage","188"],["dc.bibliographiccitation.issue","2"],["dc.bibliographiccitation.journal","Journal Of Clinical Periodontology"],["dc.bibliographiccitation.lastpage","195"],["dc.bibliographiccitation.volume","39"],["dc.contributor.author","Schliephake, Henning"],["dc.contributor.author","Roediger, Matthias"],["dc.contributor.author","Phillips, Keith"],["dc.contributor.author","McGlumphy, Edwin A."],["dc.contributor.author","Chacon, Guillermo E."],["dc.contributor.author","Larsen, Peter"],["dc.date.accessioned","2018-11-07T09:14:08Z"],["dc.date.available","2018-11-07T09:14:08Z"],["dc.date.issued","2012"],["dc.description.abstract","Aim: The aim of the present study was to evaluate an early loading protocol for surface modified implants placed in the posterior mandible. Material and Methods: A total of 134 implants with a TiO2 blasted, fluoride modified surface were inserted into the posterior mandibles of 44 patients. The implants were functionally loaded after 7 weeks of healing. Implant stability quotient (ISQ) values (during the first year), bleeding on probing (BOP), plaque accumulation and marginal bone level (MBL) were assessed until the end of the observation period of 5 years. A total of 41 patients with 123 implants completed the study. Results: No implants were lost. ISQ values decreased significantly from the time of insertion to 2 weeks and increased significantly until the 1-year follow up. BOP varied until the end of the observation period between 7.9% and 13.0%. Plaque accumulation decreased from the time of early loading to the end of the study. MBL changed from 0.59 mm at the time of implant placement to 0.80 mm at the time of early loading. Thereafter, only slight variations in MBL occurred until the end of the observation period. Conclusions: The results confirm that early loading is a promising option also in posterior edentulism of the mandible."],["dc.description.sponsorship","Astra Tech AB"],["dc.identifier.doi","10.1111/j.1600-051X.2011.01816.x"],["dc.identifier.isi","000299070000011"],["dc.identifier.pmid","22111584"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/27332"],["dc.notes.status","zu prüfen"],["dc.notes.submitter","Najko"],["dc.publisher","Wiley-blackwell"],["dc.relation.issn","0303-6979"],["dc.title","Early loading of surface modified implants in the posterior mandible-5 year results of an open prospective non-controlled study"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.status","published"],["dspace.entity.type","Publication"]]Details DOI PMID PMC WOS2015Journal Article [["dc.bibliographiccitation.firstpage","1999"],["dc.bibliographiccitation.issue","8"],["dc.bibliographiccitation.journal","Clinical Oral Investigations"],["dc.bibliographiccitation.lastpage","2006"],["dc.bibliographiccitation.volume","19"],["dc.contributor.author","Rinke, Sven"],["dc.contributor.author","Lange, Katharina"],["dc.contributor.author","Roediger, Matthias"],["dc.contributor.author","Gersdorff, Nikolaus"],["dc.date.accessioned","2018-11-07T09:49:53Z"],["dc.date.available","2018-11-07T09:49:53Z"],["dc.date.issued","2015"],["dc.description.abstract","Objectives This practice-based study evaluated the clinical performance and risk factors for biological and technical complications with conventionally luted zirconia crowns. Materials and methods Sixty-eight patients (39 female) with a total of 323 restorations placed on 219 vital teeth, 69 endodontically treated teeth (ETT), and 41 implants (incisors, 96; premolars, 89; molars, 138; observational period, 79.7 +/- 14.2 months) underwent a clinical follow-up examination and were included in the study. Time-dependent survival (in situ), success (event free), and veneering ceramic fracture (VCF) rates were calculated and analyzed relative to the following risk factors: smoking status, location of the crown, and type of abutment. Results Fifty-three complete failures were recorded. A significant influence of the abutment type on survival could be detected (p = 0.033): ETT demonstrated a significantly (p = 0.029) lower 7-year survival rate (73.8 %, 95 % confidence interval [95 % CI] 0.600-0.876) than crowns placed on implants (90.0 %, 95 % CI 0.814-0.990). The success rate of the crowns was significantly influenced by the location of the restoration (p = 0.0058). A total of 75.6 % (95 % CI 0.648-0.864) of the anterior crowns remained event free, compared to 50.4 % (95 % CI 0.388-0.621) of the molar crowns. Furthermore, the location of the crowns affected the VCF rate (p = 0.018, event-free anterior teeth 95.2 % (95 % CI 0.880-1), event-free molars 80.9 % (95 % CI 0.706-0.913)). Conclusions Survival and success rates were significantly influenced by the type of abutment and the location of the restoration."],["dc.description.sponsorship","DeguDent GmbH, Hanau, Germany"],["dc.identifier.doi","10.1007/s00784-015-1410-y"],["dc.identifier.isi","000362283100030"],["dc.identifier.pmid","25663382"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/35593"],["dc.notes.status","zu prüfen"],["dc.notes.submitter","Najko"],["dc.publisher","Springer"],["dc.publisher.place","Heidelberg"],["dc.relation.issn","1436-3771"],["dc.relation.issn","1432-6981"],["dc.title","Risk factors for technical and biological complications with zirconia single crowns"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.status","published"],["dspace.entity.type","Publication"]]Details DOI PMID PMC WOS2004Journal Article [["dc.bibliographiccitation.firstpage","F999"],["dc.bibliographiccitation.issue","5"],["dc.bibliographiccitation.journal","AMERICAN JOURNAL OF PHYSIOLOGY-RENAL PHYSIOLOGY"],["dc.bibliographiccitation.lastpage","F1010"],["dc.bibliographiccitation.volume","287"],["dc.contributor.author","Zhang, X."],["dc.contributor.author","Groves, C. E."],["dc.contributor.author","Bahn, A."],["dc.contributor.author","Barendt, W. M."],["dc.contributor.author","Prado, M. D."],["dc.contributor.author","Rodiger, M."],["dc.contributor.author","Chatsudthipong, V."],["dc.contributor.author","Burckhardt, Gerhard"],["dc.contributor.author","Wright, Stephen H."],["dc.date.accessioned","2018-11-07T10:44:01Z"],["dc.date.available","2018-11-07T10:44:01Z"],["dc.date.issued","2004"],["dc.description.abstract","We compared the characteristics of several cloned rabbit organic electrolyte (OE) transporters expressed in cultured cells with their behavior in intact rabbit renal proximal tubules (RPT) to determine the contribution of each to basolateral uptake of the weak acid ochratoxin A (OTA) and the weak base cimetidine (CIM). The activity of organic anion transporters OAT1 and OAT3 proved to be distinguishable because OAT1 had a high affinity for PAH (K(t) of 20 muM) and did not support estrone sulfate (ES) transport, whereas OAT3 had a high affinity for ES (K(t) of 4.5 muM) and a weak interaction with PAH (IC(50) > 1 mM). In contrast, both transporters robustly accumulated OTA. Intact RPT also accumulated OTA, with OAT1 and OAT3 each responsible for similar to50%: ES and PAH each reduced uptake by similar to50%, and the combination of the two eliminated mediated OTA uptake. The weak base CIM was transported by OAT3 (K(t) of 80 muM) and OCT2 (K(t) of 2 muM); OCT1 had a comparatively low affinity for CIM, and CIM uptake by OAT1 was equivocal. Intact RPT accumulated CIM, with TEA and ES reducing CIM uptake by 20 and 75%, respectively, suggesting that OAT3 plays a quantitatively more significant role in CIM uptake in the early proximal tubule than OCT1/2. In single S2 segments of RPT, ES and TEA each blocked similar to50% of CIM uptake. Thus the fractional contribution of different OE transporters to renal secretion is influenced by their affinity for substrate and relative expression level in RPT."],["dc.identifier.doi","10.1152/ajprenal.00156.2004"],["dc.identifier.isi","000224360900021"],["dc.identifier.pmid","15251863"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/47181"],["dc.notes.status","zu prüfen"],["dc.notes.submitter","Najko"],["dc.publisher","Amer Physiological Soc"],["dc.relation.issn","1931-857X"],["dc.title","Relative contribution of OAT and OCT transporters to organic electrolyte transport in rabbit proximal tubule"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.status","published"],["dspace.entity.type","Publication"]]Details DOI PMID PMC WOS2019Journal Article [["dc.bibliographiccitation.firstpage","226"],["dc.bibliographiccitation.issue","2"],["dc.bibliographiccitation.journal","Journal of Esthetic and Restorative Dentistry"],["dc.bibliographiccitation.lastpage","235"],["dc.bibliographiccitation.volume","32"],["dc.contributor.author","Rinke, Sven"],["dc.contributor.author","Pfitzenreuter, Theresia"],["dc.contributor.author","Leha, Andreas"],["dc.contributor.author","Roediger, Matthias"],["dc.contributor.author","Ziebolz, Dirk"],["dc.date.accessioned","2021-06-01T10:47:23Z"],["dc.date.available","2021-06-01T10:47:23Z"],["dc.date.issued","2019"],["dc.identifier.doi","10.1111/jerd.12542"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/85583"],["dc.language.iso","en"],["dc.notes.intern","DOI-Import GROB-425"],["dc.relation.eissn","1708-8240"],["dc.relation.issn","1496-4155"],["dc.title","Clinical evaluation of chairside‐fabricated partial crowns composed of zirconia‐reinforced lithium silicate ceramics: 3‐year results of a prospective practice‐based study"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dspace.entity.type","Publication"]]Details DOI2017Journal Article [["dc.bibliographiccitation.firstpage","357"],["dc.bibliographiccitation.issue","3"],["dc.bibliographiccitation.journal","International Endodontic Journal"],["dc.bibliographiccitation.lastpage","363"],["dc.bibliographiccitation.volume","51"],["dc.contributor.author","Rödig, T."],["dc.contributor.author","Müller, C."],["dc.contributor.author","Hoch, M."],["dc.contributor.author","Haupt, F."],["dc.contributor.author","Schulz, X."],["dc.contributor.author","Wiegand, A."],["dc.contributor.author","Rizk, M."],["dc.date.accessioned","2020-12-10T18:28:51Z"],["dc.date.available","2020-12-10T18:28:51Z"],["dc.date.issued","2017"],["dc.identifier.doi","10.1111/iej.12850"],["dc.identifier.issn","0143-2885"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/76429"],["dc.language.iso","en"],["dc.notes.intern","DOI Import GROB-354"],["dc.relation.issn","0143-2885"],["dc.relation.orgunit","Poliklinik für Präventive Zahnmedizin, Parodontologie und Kariologie"],["dc.title","Moisture content of root canal dentine affects detection of microcracks using micro-computed tomography"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dspace.entity.type","Publication"]]Details DOI2013Journal Article [["dc.bibliographiccitation.firstpage","164"],["dc.bibliographiccitation.issue","2"],["dc.bibliographiccitation.journal","The International Journal of Prosthodontics"],["dc.bibliographiccitation.lastpage","171"],["dc.bibliographiccitation.volume","26"],["dc.contributor.author","Rinke, Sven"],["dc.contributor.author","Gersdorff, Nikolaus"],["dc.contributor.author","Lange, Katharina"],["dc.contributor.author","Roediger, Matthias"],["dc.date.accessioned","2018-11-07T09:27:29Z"],["dc.date.available","2018-11-07T09:27:29Z"],["dc.date.issued","2013"],["dc.description.abstract","Purpose: The clinical performance of three-and four-unit fixed partial dentures (FPDs) with frameworks made of yttria partially stabilized zirconia was determined after a mean observational period of 84 months. Materials and Methods: Seventy-five patients were treated with 99 posterior FPDs. Fifty-one specimens were veneered with an experimental ceramic suitable for titanium and zirconia frameworks; 48 restorations were veneered with a commercially available low-fusing ceramic optimized for zirconia frameworks. All restorations were luted with zinc-phosphate cement. Statistical analysis was performed according to Kaplan-Meier; potential risk factors were analyzed using the Cox regression analysis. Results: Nineteen restorations failed completely: 12 due to technical complications, 6 due to biologic complications, and 1 for unknown reasons. The overall survival rate after 84 months was 83.4%. Thirty-two events required clinical intervention for restoration maintenance, resulting in a time-dependent success rate of 57.9% after 84 months. Nineteen dropouts occurred during the follow-up time. None of the evaluated factors showed an association with survival or success of the restorations. Conclusions: After a mean observational period of 7 years, the survival and success rates of zirconia-based posterior FPDs were inferior to those published for metal-ceramic FPDs. The majority of failures were caused by technical complications (material fractures). The main reasons for clinical intervention to maintain function were fractures of the veneering ceramic and decementations. Int J Prosthodont 2013;26:164-171. doi: 10.11607/ijp.3229"],["dc.description.sponsorship","DeguDent"],["dc.identifier.doi","10.11607/ijp.3229"],["dc.identifier.isi","000316180400011"],["dc.identifier.pmid","23476912"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/30549"],["dc.notes.status","zu prüfen"],["dc.notes.submitter","Najko"],["dc.publisher","Quintessence Publishing Co Inc"],["dc.relation.issn","0893-2174"],["dc.title","Prospective Evaluation of Zirconia Posterior Fixed Partial Dentures: 7-Year Clinical Results"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.status","published"],["dspace.entity.type","Publication"]]Details DOI PMID PMC WOS