Options
Scheidmann, Roman
Loading...
Preferred name
Scheidmann, Roman
Official Name
Scheidmann, Roman
Alternative Name
Scheidmann, R.
Main Affiliation
Now showing 1 - 2 of 2
2017Journal Article [["dc.bibliographiccitation.firstpage","35"],["dc.bibliographiccitation.journal","Cardiovascular Pathology"],["dc.bibliographiccitation.lastpage","36"],["dc.bibliographiccitation.volume","27"],["dc.contributor.author","Scheidmann, Roman"],["dc.contributor.author","Foth, Rudi"],["dc.contributor.author","Sigler, Matthias"],["dc.date.accessioned","2018-11-07T10:26:39Z"],["dc.date.available","2018-11-07T10:26:39Z"],["dc.date.issued","2017"],["dc.description.abstract","We present results of the histopathological workup of a prosthetic aortic valve which was explanted from a 31-year-old woman due to valve thrombosis during early pregnancy. Our images demonstrate nicely thrombotic material directly adherent to the pyrolytic carbon surface in a human specimen. (C) 2017 Elsevier Inc. All rights reserved."],["dc.identifier.doi","10.1016/j.carpath.2016.12.003"],["dc.identifier.isi","000397942300006"],["dc.identifier.pmid","28081513"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/43089"],["dc.notes.status","zu prüfen"],["dc.notes.submitter","PUB_WoS_Import"],["dc.publisher","Elsevier Science Inc"],["dc.relation.issn","1879-1336"],["dc.relation.issn","1054-8807"],["dc.title","Thrombosis of a mechanical prosthetic aortic valve in early pregnancy: histopathological findings"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.status","published"],["dspace.entity.type","Publication"]]Details DOI PMID PMC WOS2017-11-03Journal Article [["dc.bibliographiccitation.artnumber","9"],["dc.bibliographiccitation.issue","1"],["dc.bibliographiccitation.journal","Molecular and Cellular Pediatrics"],["dc.bibliographiccitation.volume","4"],["dc.contributor.author","Scheidmann, Roman"],["dc.contributor.author","Paul, Thomas"],["dc.contributor.author","Sigler, Matthias"],["dc.date.accessioned","2018-04-18T14:43:24Z"],["dc.date.accessioned","2021-10-27T13:21:06Z"],["dc.date.available","2018-04-18T14:43:24Z"],["dc.date.available","2021-10-27T13:21:06Z"],["dc.date.issued","2017-11-03"],["dc.date.updated","2018-04-18T14:43:24Z"],["dc.description.abstract","Introduction Transcatheter closure has become the treatment of choice for secundum atrial septal defects (ASD II), but particularly in small children, there is concern regarding procedure-related complications. Case description We report on a 10-month-old infant, body weight of 6.4 kg, with a large ASD who was referred for failure to thrive and dyspnea on exertion. Echocardiography showed two neighboring ASDs centrally located within an atrial septum with a length of 27 mm resulting in significant left-to-right shunting. During cardiac catheterization, hemodynamic significance of the defect as well as normal pulmonary vascular resistance was demonstrated. Balloon sizing of the central ASD showed a stretched defect diameter of 12 × 11 mm. A 20-mm GORE CARDIOFORM septal occluder (GCSO; Goremedical, W. L. Gore & Associates, Inc., Newark, DE, USA) was implanted without any complications. Initial trivial residual shunting resolved during 4 months of follow-up. Right ventricular dimensions declined significantly, and the boy gained body weight properly. Discussion, evaluation and conclusion As demonstrated in our report, even large ASDs can be closed safely by catheter intervention in small infants. Selection of implant device and optimal sizing is of paramount importance. The size of the delivery sheath (11 French in our patient) is a potential limitation for the GCSO in smaller infants."],["dc.identifier.doi","10.1186/s40348-017-0077-7"],["dc.identifier.pmid","29101573"],["dc.identifier.purl","https://resolver.sub.uni-goettingen.de/purl?gs-1/15178"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/91994"],["dc.language.iso","en"],["dc.language.rfc3066","en"],["dc.notes.intern","Migrated from goescholar"],["dc.publisher","Springer"],["dc.publisher.place","Berlin"],["dc.relation.eissn","2194-7791"],["dc.relation.orgunit","Universitätsmedizin Göttingen"],["dc.rights","Goescholar"],["dc.rights.holder","The Author(s)."],["dc.rights.uri","https://goescholar.uni-goettingen.de/licenses"],["dc.title","Transcatheter atrial septal defect closure in an infant (body weight 6.4 kg) using the GORE CARDIOFORM septal occluder (GCSO)"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.version","published_version"],["dspace.entity.type","Publication"]]Details DOI PMID PMC