Options
Zabel, Markus
Loading...
Preferred name
Zabel, Markus
Official Name
Zabel, Markus
Alternative Name
Zabel, M.
Main Affiliation
Now showing 1 - 10 of 31
2012Journal Article [["dc.bibliographiccitation.firstpage","819"],["dc.bibliographiccitation.issue","9"],["dc.bibliographiccitation.journal","Journal of the American College of Cardiology"],["dc.bibliographiccitation.lastpage","824"],["dc.bibliographiccitation.volume","59"],["dc.contributor.author","Vollmann, Dirk"],["dc.contributor.author","Stevenson, William G."],["dc.contributor.author","Luethje, Lars"],["dc.contributor.author","Sohns, Christian"],["dc.contributor.author","John, Roy M."],["dc.contributor.author","Zabel, Markus"],["dc.contributor.author","Michaud, Gregory F."],["dc.date.accessioned","2018-11-07T09:13:18Z"],["dc.date.available","2018-11-07T09:13:18Z"],["dc.date.issued","2012"],["dc.description.abstract","Objectives The purpose of this study was to evaluate the prevalence and mechanism of a misleading long post-pacing interval (PPI) upon entrainment of typical atrial flutter (AFL) from the cavotricuspid isthmus (CTI). Background In typical AFL, the PPI from entrainment at the CTI is expected to closely match the tachycardia cycle-length (TCL). Methods Sixty patients with confirmed CTI-dependent AFL were retrospectively analyzed and grouped into short (<= 30 ms) or long (>30 ms) PPI-TCL. Thereafter, we prospectively studied 16 patients to acquire the PPI-TCL at 4 CTI sites with entrainment at pacing cycle-lengths (PCLs) 10 to 40 ms shorter than the TCL. Conduction times during AFL and entrainment were compared in 5 segments of the AFL circuit. Results Eleven patients (18%) in the retrospective analysis had a long PPI-TCL after entrainment from the CTI. Subjects with long PPI-TCL had similar baseline characteristics but greater beat-to-beat TCL variability. In the prospective cohort, PPI-TCL was influenced by the difference between PCL and TCL and site of entrainment. Conduction delays associated with a long PPI-TCL were located predominantly in the segment activated first by the paced orthodromic wave front, and were mainly due to local pacing latency, as confirmed by the use of monophasic action potential catheters. Conclusions A long PPI upon entrainment of typical AFL from the CTI is common and due to delayed conduction with entrainment. Whether these findings apply to other macro-re-entrant tachycardias warrants further investigation. (J Am Coll Cardiol 2012; 59: 819-24) (C) 2012 by the American College of Cardiology Foundation"],["dc.identifier.doi","10.1016/j.jacc.2011.11.023"],["dc.identifier.isi","000300609300008"],["dc.identifier.pmid","22361402"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/27142"],["dc.notes.status","zu prüfen"],["dc.notes.submitter","Najko"],["dc.publisher","Elsevier Science Inc"],["dc.relation.issn","0735-1097"],["dc.title","Misleading Long Post-Pacing Interval After Entrainment of Typical Atrial Flutter From the Cavotricuspid Isthmus"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.status","published"],["dspace.entity.type","Publication"]]Details DOI PMID PMC WOS2009Journal Article Research Paper [["dc.bibliographiccitation.firstpage","273"],["dc.bibliographiccitation.issue","3"],["dc.bibliographiccitation.journal","European Journal of Heart Failure"],["dc.bibliographiccitation.lastpage","280"],["dc.bibliographiccitation.volume","11"],["dc.contributor.author","Luethje, Lars"],["dc.contributor.author","Renner, Bernd"],["dc.contributor.author","Kessels, Roger"],["dc.contributor.author","Vollmann, Dirk"],["dc.contributor.author","Raupach, Tobias"],["dc.contributor.author","Gerritse, Bart"],["dc.contributor.author","Tasci, Selcuk"],["dc.contributor.author","Schwab, Joerg O."],["dc.contributor.author","Zabel, Markus"],["dc.contributor.author","Zenker, Dieter"],["dc.contributor.author","Schott, Peter"],["dc.contributor.author","Hasenfuß, Gerd"],["dc.contributor.author","Unterberg-Buchwald, Christina"],["dc.contributor.author","Andreas, Stefan"],["dc.date.accessioned","2017-09-07T11:47:31Z"],["dc.date.available","2017-09-07T11:47:31Z"],["dc.date.issued","2009"],["dc.description.abstract","Aims The combined therapeutic impact of atrial overdrive pacing (ACIP) and cardiac resynchronization therapy (CRT) on central steep apnoea (CSA) in chronic heart failure (CHF) so far has not been investigated. We aimed to evaluate the effect of CRT alone and CRT + AOP on CSA in CHF patients and to compare the influence of CRT on CHF between CSA positive and CSA negative patients. Methods and results Thirty patients with CRT indication underwent full night polysomnography, echocardiography, exercise testing, and neurohumoral evaluation before and 3 months after CRT implantation. In CSA positive patients (60%), two additional steep studies were conducted after 3 months of CRT, with CRT alone or CRT + ACIP, in random order. Cardiac resynchronization therapy resulted in significant improvements of NYHA class, left ventricular ejection fraction, N-terminal pro-brain natriuretic peptide, VO(2)max, and quality of life irrespective of the presence of CSA. Cardiac resynchronization therapy also reduced the central apnoea-hypopnoea index (AHI) (33.6 +/- 14.3 vs. 23.8 +/- 16.9 h(-1); P < 0.01) and central apnoea index (17.3 +/- 14.1 vs. 10.9 +/- 13.9 h(-1); P < 0.01) without altering steep stages. Cardiac resynchronization therapy with atrial overdrive pacing resulted in a small but significant additional decrease of the central AHI (23.8 +/- 16.9 vs. 21.5 +/- 16.9 h(-1); P < 0.01). Conclusion In this study, CRT significantly improved CSA without altering sleep stages. Cardiac resynchronization therapy with atrial. overdrive pacing resulted in a significant but minor additional improvement of CSA. Positive effects of CRT were irrespective of the presence of CSA."],["dc.identifier.doi","10.1093/eurjhf/hfn042"],["dc.identifier.gro","3143143"],["dc.identifier.isi","000265845700008"],["dc.identifier.pmid","19147446"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/625"],["dc.notes.intern","WoS Import 2017-03-10 / Funder: Bakken Research Center, Maastricht, Netherlands"],["dc.notes.status","final"],["dc.notes.submitter","PUB_WoS_Import"],["dc.publisher","Oxford Univ Press"],["dc.relation.issn","1388-9842"],["dc.title","Cardiac resynchronization therapy and atrial overdrive pacing for the treatment of central sleep apnoea"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.subtype","original"],["dspace.entity.type","Publication"]]Details DOI PMID PMC WOS2013Journal Article Discussion [["dc.bibliographiccitation.firstpage","927"],["dc.bibliographiccitation.issue","12"],["dc.bibliographiccitation.journal","Clinical Research in Cardiology"],["dc.bibliographiccitation.lastpage","929"],["dc.bibliographiccitation.volume","102"],["dc.contributor.author","Sohns, Christian"],["dc.contributor.author","Luthje, Lars"],["dc.contributor.author","Zabel, Markus"],["dc.contributor.author","Vollmann, Dirk"],["dc.date.accessioned","2018-11-07T09:17:18Z"],["dc.date.available","2018-11-07T09:17:18Z"],["dc.date.issued","2013"],["dc.identifier.doi","10.1007/s00392-013-0612-z"],["dc.identifier.isi","000327208800009"],["dc.identifier.pmid","23989651"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/28132"],["dc.notes.status","zu prüfen"],["dc.notes.submitter","Najko"],["dc.publisher","Springer"],["dc.publisher.place","Heidelberg"],["dc.relation.issn","1861-0692"],["dc.relation.issn","1861-0684"],["dc.title","Supraventricular tachycardia with 'A-A-V' response upon ventricular entrainment and transient 2:1 AV conduction block"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.status","published"],["dc.type.subtype","letter_note"],["dspace.entity.type","Publication"]]Details DOI PMID PMC WOS2010Journal Article [["dc.bibliographiccitation.firstpage","1460"],["dc.bibliographiccitation.issue","10"],["dc.bibliographiccitation.journal","EP Europace"],["dc.bibliographiccitation.lastpage","1466"],["dc.bibliographiccitation.volume","12"],["dc.contributor.author","Seegers, Joachim"],["dc.contributor.author","Zabel, Markus"],["dc.contributor.author","Luethje, Lars"],["dc.contributor.author","Vollmann, Dirk"],["dc.date.accessioned","2018-11-07T08:38:23Z"],["dc.date.available","2018-11-07T08:38:23Z"],["dc.date.issued","2010"],["dc.description.abstract","Ventricular oversensing remains a significant problem in modern implantable cardioverter-defibrillator (ICD) systems. The role of manufacturer-related differences in device-based signal processing on the one hand and sensing lead properties on the other is largely unknown. This retrospective study aimed to evaluate and compare the incidence and mechanisms of ventricular oversensing in single- or dual-chamber ICD systems from Biotronik (BTK), Guidant (GDT), and Medtronic (MDT). In 245 consecutive patients, device function, stored episodes, and lead parameters were evaluated at implant and during 243 +/- 18 days of follow-up. Oversensing occurred in 3.3% of the patients [four T-wave oversensing (TWO), three R-wave double-sensing, and one diaphragmatic myopotentials]. The incidence of ventricular oversensing was generally low if an ICD device and an ICD lead were from one identical manufacturer (BTK: 2/68, GDT: 1/80, and MDT: 1/69; P = 0.67). In the subgroup of ICDs connected to leads from other manufacturers, however, ventricular oversensing was observed in none of 19 GDT and MDT ICDs but in 4 of 9 BTK devices (44.4%, P = 0.012). These four cases of oversensing (three R-wave double-sensing and one TWO) all occurred in BTK ICDs connected to integrated bipolar ICD leads from other manufacturers. Significant manufacturer-related differences exist in the incidence of ventricular oversensing in single- and dual-chamber ICD systems. Biotronik devices connected to integrated bipolar ICD leads from other manufacturers have an increased risk for R-wave double-sensing."],["dc.description.sponsorship","Medtronic; Biotronik"],["dc.identifier.doi","10.1093/europace/euq269"],["dc.identifier.isi","000282429700012"],["dc.identifier.pmid","20663783"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/18757"],["dc.notes.status","zu prüfen"],["dc.notes.submitter","Najko"],["dc.publisher","Oxford Univ Press"],["dc.relation.issn","1099-5129"],["dc.title","Ventricular oversensing due to manufacturer-related differences in implantable cardioverter-defibrillator signal processing and sensing lead properties"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.status","published"],["dspace.entity.type","Publication"]]Details DOI PMID PMC WOS2007Journal Article [["dc.bibliographiccitation.firstpage","275"],["dc.bibliographiccitation.issue","5"],["dc.bibliographiccitation.journal","EP Europace"],["dc.bibliographiccitation.lastpage","277"],["dc.bibliographiccitation.volume","9"],["dc.contributor.author","Vollmann, Dirk"],["dc.contributor.author","Luethje, Lars"],["dc.contributor.author","Zabel, Markus"],["dc.date.accessioned","2018-11-07T11:02:39Z"],["dc.date.available","2018-11-07T11:02:39Z"],["dc.date.issued","2007"],["dc.description.abstract","We describe the case of a patient who presented with multiple implantable cardioverter-defibrillator (ICD) shock discharges 12 months after device implantation. Upon device interrogation, intermittent oversensing of electrical noise and potential ICD lead failure were suggested by a significant increase in the sensing integrity counter (SIC), a cumulative count of very short ventricular sensed intervals. Analysis of stored episodes, however, revealed that inappropriate ICD therapy had been caused by intermittent T-wave oversensing (TWO), and that the increase of the SIC resulted from the coincidence of TWO and premature ventricular complexes (PVCs). T-wave oversensing resolved and the SIC did not increase any more during follow-up after adjustment of ventricular sensitivity. The coincidence of TWO and PVCs should therefore be considered as an uncommon cause for short ventricular sensed intervals in ICD patients presenting with a suspect increase in the SIC."],["dc.identifier.doi","10.1093/europace/eum028"],["dc.identifier.isi","000247248900004"],["dc.identifier.pmid","17369268"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/51431"],["dc.notes.status","zu prüfen"],["dc.notes.submitter","Najko"],["dc.publisher","Oxford Univ Press"],["dc.relation.issn","1099-5129"],["dc.title","Unusual cause for an increase of the sensing integrity counter in a patient with inappropriate implantable cardioverter-defibrittator therapy"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.status","published"],["dspace.entity.type","Publication"]]Details DOI PMID PMC WOS2013Journal Article Research Paper [["dc.bibliographiccitation.firstpage","684"],["dc.bibliographiccitation.issue","7"],["dc.bibliographiccitation.journal","European Heart Journal - Cardiovascular Imaging"],["dc.bibliographiccitation.lastpage","691"],["dc.bibliographiccitation.volume","14"],["dc.contributor.author","Sohns, Christian"],["dc.contributor.author","Sohns, Jan Martin"],["dc.contributor.author","Vollmann, Dirk"],["dc.contributor.author","Luethje, Lars"],["dc.contributor.author","Bergau, Leonard"],["dc.contributor.author","Dorenkamp, Marc"],["dc.contributor.author","Zwaka, Paul A."],["dc.contributor.author","Hasenfuß, Gerd"],["dc.contributor.author","Lotz, Joachim"],["dc.contributor.author","Zabel, Markus"],["dc.date.accessioned","2017-09-07T11:47:40Z"],["dc.date.available","2017-09-07T11:47:40Z"],["dc.date.issued","2013"],["dc.description.abstract","Aims This study aimed to identify whether left atrial (LA) volume assessed by multidetector computed tomography (MDCT) is related to the long-term success of pulmonary vein ablation (PVA). MDCT is used to guide PVA for the treatment of atrial fibrillation (AF). MDCT permits accurate sizing of LA dimensions. Methods and results We analysed data from 368 ablation procedures of 279 consecutive patients referred for PVA due to drug-refractory symptomatic AF (age 62 +/- 10; 58% men; 71% paroxysmal AF). Prior to the procedure, all patients underwent ECG-gated 64-MDCT scan for assessment of LA and PV anatomy, LA thrombus evaluation, LA volume estimation, and electroanatomical mapping integration. Within a mean follow-up of 356 +/- 128 days, 64% of the patients maintained sinus rhythm after the initial ablation, and 84% when including repeat PVA. LA diameter (P = 0.004), LA volume (P = 0.002), and type of AF (P = 0.001) were independent predictors of AF recurrence in univariate analysis. There was a relatively low correlation between the echocardiographic LA diameter and LA volume from MDCT (P = 0.01, r = 0.5). In multivariate analysis, paroxysmal AF (P < 0.006) and LA volume below the median value of 106 mL (P = 0.042) were significantly associated with the success of PVA, whereas LA diameter was not (P = 0.245). Analysing receiver-operator characteristics, the area under the curve for LA volume was 0.73 (P = 0.001) compared with 0.60 (P = 0.09) for LA diameter from echocardiography. Conclusion LA volume assessed by MDCT is a better predictor of AF recurrence after PVA than echocardiograpic LA diameter and can be derived from the pre-procedural imaging data set."],["dc.identifier.doi","10.1093/ehjci/jet017"],["dc.identifier.gro","3142334"],["dc.identifier.isi","000321462600013"],["dc.identifier.pmid","23435593"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/7131"],["dc.notes.intern","WoS Import 2017-03-10"],["dc.notes.status","final"],["dc.notes.submitter","PUB_WoS_Import"],["dc.publisher","Oxford Univ Press"],["dc.relation.issn","2047-2404"],["dc.title","Left atrial volumetry from routine diagnostic work up prior to pulmonary vein ablation is a good predictor of freedom from atrial fibrillation"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.subtype","original"],["dspace.entity.type","Publication"]]Details DOI PMID PMC WOS2014Journal Article Research Paper [["dc.bibliographiccitation.firstpage","1009"],["dc.bibliographiccitation.issue","11"],["dc.bibliographiccitation.journal","RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren"],["dc.bibliographiccitation.lastpage","1015"],["dc.bibliographiccitation.volume","186"],["dc.contributor.author","Staab, Wieland"],["dc.contributor.author","Sohns, Christian"],["dc.contributor.author","Zwaka, Paul A."],["dc.contributor.author","Sohns, Jan Martin"],["dc.contributor.author","Schwarz, Alexander"],["dc.contributor.author","Schneider, S."],["dc.contributor.author","Vollmann, Dirk"],["dc.contributor.author","Zabel, Markus"],["dc.contributor.author","Hasenfuß, Gerd"],["dc.contributor.author","Lotz, Joachim"],["dc.date.accessioned","2017-09-07T11:45:26Z"],["dc.date.available","2017-09-07T11:45:26Z"],["dc.date.issued","2014"],["dc.description.abstract","Purpose: Evaluation of a new cardiac MDCT protocol using a split-bolus contrast injection protocol and single MDCT scan for reliable diagnosis of LA/LAA thrombi in comparison to TEE, optimizing radiation exposure and use of contrast agent. Materials and Methods: A total of 182 consecutive patients with drug refractory AF scheduled for PVI (62.6 % male, mean age: 64.1 +/- 10.2 years) underwent routine diagnostic work including TEE and cardiac MDCT for the evaluation of LA/LAA anatomy and thrombus formation between November 2010 and March 2012. Contrast media injection was split into a pre-bolus of 30 ml and main bolus of 70 ml iodinated contrast agent separated by a short time delay. Results: In this study, split-bolus cardiac MDCT identified 14 of 182 patients with filling defects of the LA/LAA. In all of these 14 patients, abnormalities were found in TEE. All 5 of the 14 patients with thrombus formation in cardiac MDCT were confirmed by TEE. Conclusion: MDCT was 100 % accurate for thrombus, with strong but not perfect overall results for SEC equivalent on MDCT. Key Points: Patients with no filling defect or thrombus in MDCT in the LA/LAA region are unlikely to have thrombus and may undergo PVI without TEE. Here, the role of an additional TEE in pre-procedural management prior to PVI in patients with AF has to be redefined. Using a split-bolus injection protocol increases the diagnostic accuracy of thrombus in the LA/LAA region."],["dc.identifier.doi","10.1055/s-0034-1366247"],["dc.identifier.gro","3142029"],["dc.identifier.isi","000344356700003"],["dc.identifier.pmid","24729408"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/3756"],["dc.language.iso","en"],["dc.notes.intern","WoS Import 2017-03-10"],["dc.notes.status","zu prüfen"],["dc.notes.submitter","PUB_WoS_Import"],["dc.relation.eissn","1438-9010"],["dc.relation.issn","1438-9029"],["dc.title","Split-Bolus Single-Phase Cardiac Multidetector Computed Tomography for Reliable Detection of Left Atrial Thrombus: Comparison to Transesophageal Echocardiography"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.subtype","original"],["dspace.entity.type","Publication"]]Details DOI PMID PMC WOS2013Journal Article Discussion [["dc.bibliographiccitation.firstpage","473"],["dc.bibliographiccitation.issue","6"],["dc.bibliographiccitation.journal","Clinical Research in Cardiology"],["dc.bibliographiccitation.lastpage","476"],["dc.bibliographiccitation.volume","102"],["dc.contributor.author","Schroeter, Marco R."],["dc.contributor.author","Hasenfuß, Gerd"],["dc.contributor.author","Zabel, Markus"],["dc.contributor.author","Vollmann, Dirk"],["dc.date.accessioned","2017-09-07T11:47:41Z"],["dc.date.available","2017-09-07T11:47:41Z"],["dc.date.issued","2013"],["dc.identifier.doi","10.1007/s00392-013-0557-2"],["dc.identifier.gro","3142348"],["dc.identifier.isi","000319081700008"],["dc.identifier.pmid","23529655"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/7286"],["dc.notes.intern","WoS Import 2017-03-10"],["dc.notes.status","final"],["dc.notes.submitter","PUB_WoS_Import"],["dc.relation.issn","1861-0684"],["dc.title","Atrial standstill in a patient with progressive severe heart failure"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.subtype","letter_note"],["dspace.entity.type","Publication"]]Details DOI PMID PMC WOS2011Journal Article [["dc.bibliographiccitation.firstpage","1699"],["dc.bibliographiccitation.issue","12"],["dc.bibliographiccitation.journal","Pacing and Clinical Electrophysiology"],["dc.bibliographiccitation.lastpage","1703"],["dc.bibliographiccitation.volume","34"],["dc.contributor.author","Seegers, Joachim"],["dc.contributor.author","Zabel, Markus"],["dc.contributor.author","Sweeney, Michael O."],["dc.contributor.author","Vollmann, Dirk"],["dc.date.accessioned","2018-11-07T08:49:14Z"],["dc.date.available","2018-11-07T08:49:14Z"],["dc.date.issued","2011"],["dc.description.sponsorship","Biotronik; Medtronic"],["dc.identifier.doi","10.1111/j.1540-8159.2011.03099.x"],["dc.identifier.isi","000297940700021"],["dc.identifier.pmid","21501178"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/21409"],["dc.notes.status","zu prüfen"],["dc.notes.submitter","Najko"],["dc.publisher","Wiley-blackwell"],["dc.relation.issn","0147-8389"],["dc.title","Inappropriate Sensing in a Single-Chamber ICDuWhat is the Mechanism?"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.status","published"],["dspace.entity.type","Publication"]]Details DOI PMID PMC WOS2014Conference Abstract [["dc.bibliographiccitation.journal","European Heart Journal"],["dc.bibliographiccitation.volume","35"],["dc.contributor.author","Exposito, P. Munoz"],["dc.contributor.author","Seegers, Joachim"],["dc.contributor.author","Luethje, Lars"],["dc.contributor.author","Vollmann, Dirk"],["dc.contributor.author","Hasenfuß, Gerd"],["dc.contributor.author","Zabel, M."],["dc.date.accessioned","2018-11-07T09:35:36Z"],["dc.date.available","2018-11-07T09:35:36Z"],["dc.date.issued","2014"],["dc.format.extent","939"],["dc.identifier.isi","000343001305332"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/32422"],["dc.notes.status","zu prüfen"],["dc.notes.submitter","Najko"],["dc.publisher","Oxford Univ Press"],["dc.publisher.place","Oxford"],["dc.relation.eventlocation","Barcelona, SPAIN"],["dc.relation.issn","1522-9645"],["dc.relation.issn","0195-668X"],["dc.title","Usefulness of approximate body-surface-potential-mapping (a-bspm) for risk stratification"],["dc.type","conference_abstract"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.status","published"],["dspace.entity.type","Publication"]]Details WOS