Now showing 1 - 4 of 4
  • 2014Journal Article Research Paper
    [["dc.bibliographiccitation.artnumber","088102"],["dc.bibliographiccitation.firstpage","3"],["dc.bibliographiccitation.issue","8"],["dc.bibliographiccitation.journal","Physical Review Letters"],["dc.bibliographiccitation.lastpage","7"],["dc.bibliographiccitation.volume","112"],["dc.contributor.author","Weinhausen, Britta"],["dc.contributor.author","Saldanha, Oliva"],["dc.contributor.author","Wilke, Robin N."],["dc.contributor.author","Dammann, Christian"],["dc.contributor.author","Priebe, Marius"],["dc.contributor.author","Burghammer, Manfred"],["dc.contributor.author","Sprung, Michael"],["dc.contributor.author","Köster, Sarah"],["dc.date.accessioned","2017-09-07T11:46:29Z"],["dc.date.available","2017-09-07T11:46:29Z"],["dc.date.issued","2014"],["dc.description.abstract","High-resolution x-ray imaging techniques offer a variety of possibilities for studying the nanoscale structure of biological cells. A challenging task remains the study of cells by x rays in their natural, aqueous environment. Here, we overcome this limitation by presenting scanning x-ray diffraction measurements with beam sizes in the range of a few hundred nm on living and fixed-hydrated eukaryotic cells in microfluidic devices which mimic a native environment. The direct comparison between fixed-hydrated and living cells shows distinct differences in the scattering signal, pointing to structural changes on the order of 30 to 50 nm."],["dc.identifier.doi","10.1103/PhysRevLett.112.088102"],["dc.identifier.gro","3142182"],["dc.identifier.isi","000331957600012"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/5443"],["dc.language.iso","en"],["dc.notes.intern","WoS Import 2017-03-10"],["dc.notes.status","final"],["dc.notes.submitter","PUB_WoS_Import"],["dc.relation.eissn","1079-7114"],["dc.relation.issn","0031-9007"],["dc.relation.orgunit","Institut für Röntgenphysik"],["dc.relation.workinggroup","RG Köster (Cellular Biophysics)"],["dc.subject.gro","x-ray imaging"],["dc.subject.gro","x-ray scattering"],["dc.subject.gro","cellular biophysics"],["dc.subject.gro","microfluidics"],["dc.title","Scanning X-Ray Nanodiffraction on Living Eukaryotic Cells in Microfluidic Environments"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.subtype","original_ja"],["dspace.entity.type","Publication"]]
    Details DOI WOS
  • 2015Conference Paper
    [["dc.contributor.author","Osterhoff, Markus"],["dc.contributor.author","Döring, Florian"],["dc.contributor.author","Eberl, Christian"],["dc.contributor.author","Wilke, Robin N."],["dc.contributor.author","Wallentin, Jesper"],["dc.contributor.author","Krebs, Hans-Ulrich"],["dc.contributor.author","Sprung, Michael"],["dc.contributor.author","Salditt, Tim"],["dc.date.accessioned","2017-09-07T11:54:07Z"],["dc.date.available","2017-09-07T11:54:07Z"],["dc.date.issued","2015"],["dc.identifier.doi","10.1117/12.2187799"],["dc.identifier.gro","3145110"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/2810"],["dc.notes.intern","Crossref Import"],["dc.notes.status","public"],["dc.publisher","SPIE"],["dc.publisher.place","Bellingham, Wash."],["dc.relation","SFB 755: Nanoscale Photonic Imaging"],["dc.relation.conference","X-ray nanoimaging: instruments and methods"],["dc.relation.eventend","2015-08-13"],["dc.relation.eventlocation","San Diego, Calif."],["dc.relation.eventstart","2015-08-12"],["dc.relation.isbn","978-1-62841-758-6"],["dc.relation.ispartof","X-ray nanoimaging: instruments and methods II: 12 - 13 August 2015, San Diego, California, United States"],["dc.relation.orgunit","Institut für Röntgenphysik"],["dc.relation.workinggroup","RG Salditt (Structure of Biomolecular Assemblies and X-Ray Physics)"],["dc.subject.gro","x-ray optics"],["dc.subject.gro","x-ray imaging"],["dc.title","Progress on multi-order hard x-ray imaging with multilayer zone plates"],["dc.type","conference_paper"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","no"],["dspace.entity.type","Publication"]]
    Details DOI
  • 2014Journal Article Research Paper
    [["dc.bibliographiccitation.firstpage","7071"],["dc.bibliographiccitation.issue","12"],["dc.bibliographiccitation.journal","Nano Letters"],["dc.bibliographiccitation.lastpage","7076"],["dc.bibliographiccitation.volume","14"],["dc.contributor.author","Wallentin, Jesper"],["dc.contributor.author","Osterhoff, Markus"],["dc.contributor.author","Wilke, Robin N."],["dc.contributor.author","Persson, Karl-Magnus"],["dc.contributor.author","Wernersson, Lars-Erik"],["dc.contributor.author","Sprung, Michael"],["dc.contributor.author","Salditt, Tim"],["dc.date.accessioned","2017-09-07T11:45:23Z"],["dc.date.available","2017-09-07T11:45:23Z"],["dc.date.issued","2014"],["dc.description.abstract","Submicron sized sensors could allow higher resolution in X-ray imaging and diffraction measurements, which are ubiquitous for materials science and medicine. We present electrical measurements of a single 100 nm diameter InP nanowire transistor exposed to hard X-rays. The X-ray induced conductance is over 5 orders of magnitude larger than expected from reported data for X-ray absorption and carrier lifetimes. Time-resolved measurements show very long characteristic lifetimes on the order of seconds, tentatively attributed to long-lived traps, which give a strong amplification effect. As a proof of concept, we use the nanowire to directly image an X-ray nanofocus with submicron resolution."],["dc.identifier.doi","10.1021/nl5040545"],["dc.identifier.gro","3142008"],["dc.identifier.isi","000346322800049"],["dc.identifier.pmid","25419623"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/3523"],["dc.language.iso","en"],["dc.notes.intern","WoS Import 2017-03-10 / Funder: K. A. Wallenberg Foundation; Deutsche Forschungsgemeinschaft [SFB 755]"],["dc.notes.status","final"],["dc.notes.submitter","PUB_WoS_Import"],["dc.relation.eissn","1530-6992"],["dc.relation.issn","1530-6984"],["dc.relation.orgunit","Institut für Röntgenphysik"],["dc.relation.workinggroup","RG Salditt (Structure of Biomolecular Assemblies and X-Ray Physics)"],["dc.subject.gro","x-ray imaging"],["dc.title","Hard X-ray Detection Using a Single nm Diameter Nanowire"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.subtype","original_ja"],["dspace.entity.type","Publication"]]
    Details DOI PMID PMC WOS
  • 2015Journal Article Research Paper
    [["dc.bibliographiccitation.firstpage","867"],["dc.bibliographiccitation.journal","Journal of Synchrotron Radiation"],["dc.bibliographiccitation.lastpage","878"],["dc.bibliographiccitation.volume","22"],["dc.contributor.author","Salditt, Tim"],["dc.contributor.author","Osterhoff, Markus"],["dc.contributor.author","Krenkel, Martin"],["dc.contributor.author","Wilke, Robin N."],["dc.contributor.author","Priebe, Marius"],["dc.contributor.author","Bartels, Matthias"],["dc.contributor.author","Kalbfleisch, Sebastian"],["dc.contributor.author","Sprung, Michael"],["dc.date.accessioned","2017-09-07T11:43:44Z"],["dc.date.available","2017-09-07T11:43:44Z"],["dc.date.issued","2015"],["dc.description.abstract","A compound optical system for coherent focusing and imaging at the nanoscale is reported, realised by high-gain fixed-curvature elliptical mirrors in combination with X-ray waveguide optics or different cleaning apertures. The key optical concepts are illustrated, as implemented at the Gottingen Instrument for Nano-Imaging with X-rays (GINIX), installed at the P10 coherence beamline of the PETRA III storage ring at DESY, Hamburg, and examples for typical applications in biological imaging are given. Characteristic beam configurations with the recently achieved values are also described, meeting the different requirements of the applications, such as spot size, coherence or bandwidth. The emphasis of this work is on the different beam shaping, filtering and characterization methods."],["dc.identifier.doi","10.1107/S1600577515007742"],["dc.identifier.gro","3141875"],["dc.identifier.isi","000357407900001"],["dc.identifier.pmid","26134789"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/2045"],["dc.language.iso","en"],["dc.notes.intern","WoS Import 2017-03-10"],["dc.notes.status","final"],["dc.notes.submitter","PUB_WoS_Import"],["dc.relation","SFB 755: Nanoscale Photonic Imaging"],["dc.relation.eissn","1600-5775"],["dc.relation.issn","0909-0495"],["dc.relation.orgunit","Institut für Röntgenphysik"],["dc.relation.workinggroup","RG Salditt (Structure of Biomolecular Assemblies and X-Ray Physics)"],["dc.subject.gro","x-ray optics"],["dc.subject.gro","x-ray imaging"],["dc.subject.gro","x-ray scattering"],["dc.title","Compound focusing mirror and X-ray waveguide optics for coherent imaging and nano-diffraction"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.subtype","original_ja"],["dspace.entity.type","Publication"]]
    Details DOI PMID PMC WOS