Options
Dullin, Christian
Loading...
Preferred name
Dullin, Christian
Official Name
Dullin, Christian
Alternative Name
Dullin, C.
Main Affiliation
Now showing 1 - 4 of 4
2015Journal Article Research Paper [["dc.bibliographiccitation.firstpage","143"],["dc.bibliographiccitation.journal","Journal of Synchrotron Radiation"],["dc.bibliographiccitation.lastpage","155"],["dc.bibliographiccitation.volume","22"],["dc.contributor.author","Dullin, Christian"],["dc.contributor.author","dal Monego, Simeone"],["dc.contributor.author","Larsson, Emanuel"],["dc.contributor.author","Mohammadi, Sara"],["dc.contributor.author","Krenkel, Martin"],["dc.contributor.author","Garrovo, Chiara"],["dc.contributor.author","Biffi, Stefania"],["dc.contributor.author","Lorenzon, Andrea"],["dc.contributor.author","Markus, Andrea"],["dc.contributor.author","Napp, Joanna"],["dc.contributor.author","Salditt, Tim"],["dc.contributor.author","Accardo, Agostino"],["dc.contributor.author","Alves, Frauke"],["dc.contributor.author","Tromba, Giuliana"],["dc.date.accessioned","2017-09-07T11:44:46Z"],["dc.date.available","2017-09-07T11:44:46Z"],["dc.date.issued","2015"],["dc.description.abstract","Functionalized computed tomography (CT) in combination with labelled cells is virtually non-existent due to the limited sensitivity of X-ray-absorption-based imaging, but would be highly desirable to realise cell tracking studies in entire organisms. In this study we applied in-line free propagation X-ray phase-contrast CT (XPCT) in an allergic asthma mouse model to assess structural changes as well as the biodistribution of barium-labelled macrophages in lung tissue. Alveolar macrophages that were barium-sulfate-loaded and fluorescent-labelled were instilled intratracheally into asthmatic and control mice. Mice were sacrificed after 24 h, lungs were kept in situ, inflated with air and scanned utilizing XPCT at the SYRMEP beamline (Elettra Synchrotron Light Source, Italy). Single-distance phase retrieval was used to generate data sets with ten times greater contrast-to-noise ratio than absorption-based CT (in our setup), thus allowing to depict and quantify structural hallmarks of asthmatic lungs such as reduced air volume, obstruction of airways and increased soft-tissue content. Furthermore, we found a higher concentration as well as a specific accumulation of the barium-labelled macrophages in asthmatic lung tissue. It is believe that XPCT will be beneficial in preclinical asthma research for both the assessment of therapeutic response as well as the analysis of the role of the recruitment of macrophages to inflammatory sites."],["dc.identifier.doi","10.1107/S1600577514021730"],["dc.identifier.fs","608140"],["dc.identifier.gro","3141991"],["dc.identifier.isi","000346850200022"],["dc.identifier.pmid","25537601"],["dc.identifier.purl","https://resolver.sub.uni-goettingen.de/purl?gs-1/11558"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/3334"],["dc.language.iso","en"],["dc.notes.intern","WoS Import 2017-03-10"],["dc.notes.intern","Merged from goescholar"],["dc.notes.intern","Merged from goescholar"],["dc.notes.status","final"],["dc.notes.submitter","PUB_WoS_Import"],["dc.relation","info:eu-repo/grantAgreement/EC/FP7/230739/EU//P3AGI"],["dc.relation.eissn","1600-5775"],["dc.relation.issn","0909-0495"],["dc.relation.orgunit","Fakultät für Physik"],["dc.relation.orgunit","Institut für Röntgenphysik"],["dc.relation.workinggroup","RG Salditt (Structure of Biomolecular Assemblies and X-Ray Physics)"],["dc.rights","Goescholar"],["dc.rights.uri","https://goescholar.uni-goettingen.de/licenses"],["dc.subject.gro","x-ray imaging"],["dc.subject.gro","biomedical tomography"],["dc.title","Functionalized synchrotron in-line phase-contrast computed tomography: a novel approach for simultaneous quantification of structural alterations and localization of barium-labelled alveolar macrophages within mouse lung samples"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.subtype","original_ja"],["dc.type.version","published_version"],["dspace.entity.type","Publication"]]Details DOI PMID PMC WOS2016Journal Article Research Paper [["dc.bibliographiccitation.artnumber","035007"],["dc.bibliographiccitation.issue","3"],["dc.bibliographiccitation.journal","AIP Advances"],["dc.bibliographiccitation.volume","6"],["dc.contributor.author","Krenkel, Martin"],["dc.contributor.author","Toepperwien, Mareike"],["dc.contributor.author","Dullin, Christian"],["dc.contributor.author","Alves, Frauke"],["dc.contributor.author","Salditt, Tim"],["dc.date.accessioned","2017-09-07T11:54:36Z"],["dc.date.available","2017-09-07T11:54:36Z"],["dc.date.issued","2016"],["dc.description.abstract","We have performed high-resolution phase-contrast tomography on whole mice with a laboratory setup. Enabled by a high-brilliance liquid- metal- jet source, we show the feasibility of propagation-based phase contrast in local tomography even in the presence of strongly absorbing surrounding tissue as it is the case in small animal imaging of the lung. We demonstrate the technique by reconstructions of the mouse lung for two different fields of view, covering the whole organ, and a zoom to the local finer structure of terminal airways and alveoli. With a resolution of a few micrometers and the wide availability of the technique, studies of larger biological samples at the cellular level become possible. (c) 2016 Author(s)."],["dc.identifier.doi","10.1063/1.4943898"],["dc.identifier.gro","3141718"],["dc.identifier.isi","000373684200008"],["dc.identifier.purl","https://resolver.sub.uni-goettingen.de/purl?gs-1/13246"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/302"],["dc.notes.intern","WoS Import 2017-03-10 / Funder: BMBF-Verbundforschung; [SFB 755]"],["dc.notes.intern","Merged from goescholar"],["dc.notes.intern","Merged from goescholar"],["dc.notes.status","final"],["dc.notes.submitter","PUB_WoS_Import"],["dc.relation.issn","2158-3226"],["dc.relation.orgunit","Fakultät für Physik"],["dc.relation.orgunit","Institut für Röntgenphysik"],["dc.relation.workinggroup","RG Salditt (Structure of Biomolecular Assemblies and X-Ray Physics)"],["dc.rights","CC BY 4.0"],["dc.rights.uri","https://creativecommons.org/licenses/by/4.0"],["dc.subject.gro","x-ray imaging"],["dc.subject.gro","biomedical tomography"],["dc.title","Propagation-based phase-contrast tomography for high-resolution lung imaging with laboratory sources"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.subtype","original_ja"],["dc.type.version","published_version"],["dspace.entity.type","Publication"]]Details DOI WOS2015Book Chapter [["dc.bibliographiccitation.firstpage","96"],["dc.bibliographiccitation.lastpage","97"],["dc.bibliographiccitation.volume","Life Sciences and Cultural Heritage, Elettra - SYRMEP"],["dc.contributor.author","Dullin, Christian"],["dc.contributor.author","dal Monego, Simeone"],["dc.contributor.author","Larsson, Emanuel"],["dc.contributor.author","Mohammadi, Sara"],["dc.contributor.author","Krenkel, Martin"],["dc.contributor.author","Garrovo, Chiara"],["dc.contributor.author","Biffi, Stefania"],["dc.contributor.author","Lorenzon, Andrea"],["dc.contributor.author","Markus, Andrea"],["dc.contributor.author","Napp, Joanna"],["dc.contributor.author","Salditt, Tim"],["dc.contributor.author","Accardo, Agostino"],["dc.contributor.author","Alves, Frauke"],["dc.contributor.author","Tromba, G."],["dc.date.accessioned","2020-03-11T09:34:33Z"],["dc.date.available","2020-03-11T09:34:33Z"],["dc.date.issued","2015"],["dc.description.abstract","We successfully applied synchrotron in-line phase contrast CT in combination with single distance phase retrieval to image lungs of asthmatic and healthy mice in high resolution in situ. The increased image quality in phase contrast CT added functional contrast to CT which enabled simultaneous i\\) anatomical imaging for the discrimination of asthmatic from healthy mice based on alterations of their lung structure as well as ii\\) functional imaging to track the location of barium sulfate loaded intratracheally instilled alveolar macrophages. Link to fulltext: http://www.elettra.eu/images/Documents/SCIENCE/Elettra%20HL%202015.pdf"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/63295"],["dc.language.iso","en"],["dc.publisher","Elettra - Sincrotrone Trieste"],["dc.publisher.place","Trieste"],["dc.relation.ispartof","ELETTRA HIGHLIGHTS 2014-2015"],["dc.title","Simultaneous localization of labelled macrophages and structural analysis of asthmatic mice by phase contrast CT"],["dc.type","book_chapter"],["dc.type.internalPublication","yes"],["dspace.entity.type","Publication"]]Details2015Journal Article Research Paper [["dc.bibliographiccitation.artnumber","09973"],["dc.bibliographiccitation.journal","Scientific Reports"],["dc.bibliographiccitation.volume","5"],["dc.contributor.author","Krenkel, Martin"],["dc.contributor.author","Markus, Andrea"],["dc.contributor.author","Bartels, Matthias"],["dc.contributor.author","Dullin, Christian"],["dc.contributor.author","Alves, Frauke"],["dc.contributor.author","Salditt, Tim"],["dc.date.accessioned","2017-09-07T11:44:24Z"],["dc.date.available","2017-09-07T11:44:24Z"],["dc.date.issued","2015"],["dc.description.abstract","We have performed x-ray phase-contrast tomography on mouse lung tissue. Using a divergent x-ray beam generated by nanoscale focusing, we used zoom tomography to produce three-dimensional reconstructions with selectable magnification, resolution, and field of view. Thus, macroscopic tissue samples extending over several mm can be studied in sub-cellular-level structural detail. The zoom capability and, in particular, the high dose efficiency are enabled by the near-perfect exit wavefront of an optimized x-ray waveguide channel. In combination with suitable phase-retrieval algorithms, challenging radiation-sensitive and low-contrast samples can be reconstructed with minimal artefacts. The dose efficiency of the method is demonstrated by the reconstruction of living macrophages both with and without phagocytized contrast agents. We also used zoom tomography to visualize barium-labelled macrophages in the context of morphological structures in asthmatic and healthy mouse lung tissue one day after intratracheal application. The three-dimensional reconstructions showed that the macrophages predominantly localized to the alveoli, but they were also found in bronchial walls, indicating that these cells might be able to migrate from the lumen of the bronchi through the epithelium."],["dc.identifier.doi","10.1038/srep09973"],["dc.identifier.fs","615791"],["dc.identifier.gro","3141904"],["dc.identifier.isi","000354310200001"],["dc.identifier.pmid","25966338"],["dc.identifier.purl","https://resolver.sub.uni-goettingen.de/purl?gs-1/13625"],["dc.identifier.uri","https://resolver.sub.uni-goettingen.de/purl?gro-2/2367"],["dc.language.iso","en"],["dc.notes.intern","WoS Import 2017-03-10"],["dc.notes.intern","Merged from goescholar"],["dc.notes.status","final"],["dc.notes.submitter","PUB_WoS_Import"],["dc.relation.issn","2045-2322"],["dc.relation.orgunit","Fakultät für Physik"],["dc.relation.orgunit","Institut für Röntgenphysik"],["dc.relation.workinggroup","RG Salditt (Structure of Biomolecular Assemblies and X-Ray Physics)"],["dc.rights","CC BY 4.0"],["dc.subject.gro","x-ray imaging"],["dc.subject.gro","biomedical tomography"],["dc.subject.mesh","Animals"],["dc.subject.mesh","Cell Line, Transformed"],["dc.subject.mesh","Cell Movement"],["dc.subject.mesh","Macrophages, Alveolar"],["dc.subject.mesh","Mice"],["dc.subject.mesh","Pulmonary Alveoli"],["dc.subject.mesh","Respiratory Mucosa"],["dc.subject.mesh","Tomography, X-Ray"],["dc.title","Phase-contrast zoom tomography reveals precise locations of macrophages in mouse lungs"],["dc.type","journal_article"],["dc.type.internalPublication","yes"],["dc.type.peerReviewed","yes"],["dc.type.subtype","original_ja"],["dc.type.version","published_version"],["dspace.entity.type","Publication"]]Details DOI PMID PMC WOS